Managing Faults 45
Note The Service Required LED is also turned on for PSH diagnosed faults.
Related Information
“Diagnostic Flowchart” on page 11
“Solaris Predictive Self-Healing Overview” on page 17
“ILOM-to-ALOM CMT Command Reference” on page 53
SPARC Enterprise T5440 Server Administration Guide
Integrated Lights Out Manager 3.0 Supplement for SPARC Enterprise T5440 Server
Detect Faults Identified by the Solaris PSH
Facility Using the ILOM fmdump Command
The ILOM fmdump command displays the list of faults detected by the Solaris PSH
facility and identifies the faulty FRU for a particular EVENT_ID (UUID).
Note Do not use fmdump to verify that a FRU replacement has cleared a fault,
because the output of fmdump is the same after the FRU has been replaced. Use the
fmadm faulty command to verify that the fault has cleared. See “Clear Faults
Detected by PSH” on page 49.
1. Check the event log using the fmdump command with -v for verbose output.
In CODE EXAMPLE: Output from the fmdump -v Command on page 46, a fault
is displayed, indicating the following details.
Date and time of the fault (Jul 31 12:47:42.2007)
Universal Unique Identifier (UUID). The UUID is unique for every fault
(fd940ac2-d21e-c94a-f258-f8a9bb69d05b)
Message identifier, which can be used to obtain additional fault information
(SUN4V-8000-JA)
Faulted FRU. The information provided in the example includes the part
number of the FRU (part=541215101) and the serial number of the FRU
(serial=101083). The Location field provides the name of the FRU. In
CODE EXAMPLE: Output from the fmdump -v Command on page 46 the FRU
name is MB, meaning the motherboard.