Performing Node Reconfiguration 157
Recovering from a Failed CMP/Memory
Module
If your system experiences a complete CMP/memory module failure, do one of the
following:
1. Replace the failed CMP/memory module.
2. If a replacement CMP module is not available, remove the failed CMP module and
replace it with a CMP from a different slot that does not have any directly
connected I/O devices in use (see TABLE: Devices controlled by CMPs in 2P
systems on page 164 andTABLE: Devices controlled by CMPs in 4P systems on
page 165). If this leaves a memory module without its associated CMP module,
remove the memory module.
Note At a minimum, a functioning CMP module must be installed in CMP Slot 0.
If you are performing a node reconfiguration following a failure in CMP Slot 0, you
must move one of the remaining CMP modules to CMP Slot 0.
3. If neither option (1) nor (2) is possible, you must do the following:
“Temporarily Disable All Memory Modules” on page 160
“Reconfigure the I/O and PCIe Fabric” on page 158
“Re-Enable All Memory Modules” on page 161
“Reset the LDoms Guest Configuration” on page 162
Related Information
“Managing Faults” on page 9
“Servicing CMP/Memory Modules” on page 98
“Servicing FB-DIMMs” on page 104
“I/O Connections to CMP/Memory Modules” on page 156
“Reconfiguring I/O Device Nodes” on page 158
“System Bus Topology” on page 162
“I/O Fabric in 2P Configuration” on page 164
“I/O Fabric in 4P Configuration” on page 165
Vista de página 182
1 2 ... 178 179 180 181 182 183 184 185 186 187 188 ... 213 214

Comentários a estes Manuais

Sem comentários