106 SPARC Enterprise T5440 Server Service Manual July 2009
3. Line up the replacement FB-DIMM with the connector.
Align the FB-DIMM notch with the key in the connector. This ensures that the
FB-DIMM is oriented correctly.
4. Push the FB-DIMM into the connector until the ejector tabs lock the FB-DIMM
in place.
If the FB-DIMM does not easily seat into the connector, verify that the orientation
of the FB-DIMM is correct. If the orientation is reversed, damage to the FB-DIMM
might occur.
5. Repeat Step 2 through Step 4 until all replacement FB-DIMMs are installed.
Next Steps
“Install a CMP/Memory Module” on page 100
“Install the Top Cover” on page 150
“Slide the Server Into the Rack” on page 151
“Power On the Server” on page 153
Verify FB-DIMM Replacement
1. Access the ILOM -> prompt.
Refer to the Integrated Lights Out Manager 3.0 Supplement for SPARC Enterprise
T5440 Server for instructions.
2. Run the show faulty command to determine how to clear the fault.
The method you use to clear a fault depends on how the fault is identified by the
showfaults command.
Examples:
If the fault is a host-detected fault (displays a UUID), continue to Step 3. For
example:
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |