Servicing Field-Replaceable Units 129
Servicing the Fan Tray Carriage
You must remove the fan tray carriage in order to service the following components:
Hard disk backplane
Motherboard
Front control panel
Front I/O board
Related Information
“Servicing Fan Trays” on page 81
“Servicing the Hard Drive Backplane” on page 132
“Servicing the Motherboard” on page 135
“Servicing the Front Control Panel” on page 144
“Servicing the Front I/O Board” on page 146
Remove the Fan Tray Carriage
Before you begin, complete these tasks:
Read the section, “Safety Information” on page 59.
Power off the server using one of the methods described in the section, “Powering
Off the System” on page 63.
“Extend the Server to the Maintenance Position” on page 66
“Perform Electrostatic Discharge Antistatic Prevention Measures” on page 69
“Remove a Fan Tray” on page 83
Note You must remove all four fan trays.
“Remove the Top Cover” on page 69
“Remove a CMP/Memory Module” on page 99
Note You must remove all CPU modules and memory modules from the system.
Do the following: