viii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Remove the Top Cover 67Servicing Hard Drives 69Hard Drive Servicing Overview

Página 3 - Service Manual

74 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – SPARC Enterprise T5120 servers might have up to seven blank panelscoverin

Página 4

Servicing Hard Drives 754. At the Solaris prompt, type the cfgadm -al command. This will list all drivesin the device tree, including drives that are

Página 5

76 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20097. At the Solaris prompt, type the cfgadm -al command to list all drives in thed

Página 6

Servicing Hard Drives 77Four-Drive Capable BackplaneConfiguration ReferenceThe following table shows the physical hard drive locations in a four-drive

Página 7 - Contents

78 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Eight-Drive Capable BackplaneConfiguration ReferenceThe first table below identi

Página 8

Servicing Hard Drives 79Sixteen-Drive Capable BackplaneConfiguration ReferenceThe first table below identifies the hard drive slot numbering in a sixt

Página 9

80 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Install a Hard Drive” on page 73 “Remove a Hard Drive” on

Página 10

81Servicing Motherboard ComponentsThese topics explain how to replace the motherboard and its components in theSPARC Enterprise T5120 and SPARC Enterp

Página 11

82 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Memory Fault Handling OverviewA variety of features play a role in how the memor

Página 12

Servicing Motherboard Components 83▼ Identify Faulty FB-DIMMs Using the showfaulty CommandThe ILOM show faulty command displays current system faults,

Página 13

Contents ix▼ Remove a PCIe/XAUI Riser 102▼ Install a PCIe/XAUI Riser 104▼ Remove a PCIe or XAUI Card 106▼ Install a PCIe or XAUI Card 107PCIe/XAUI Car

Página 14

84 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The FB-DIMM Fault Locator button is near the left edge of the motherboard

Página 15 - Before You Read This Document

Servicing Motherboard Components 85Related Information “Identify Faulty FB-DIMMs Using the show faulty Command” on page 83▼ Remove FB-DIMMsBefore beg

Página 16

86 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing FB-DIMMs6. Press the Fault Locator button on the motherboard to

Página 17 - Related Documentation

Servicing Motherboard Components 879. Place the FB-DIMM on an antistatic mat.10. Repeat Step 7 through Step 9 for any other FB-DIMMs you intend to rem

Página 18 - Title Description Manual Code

88 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing FB-DIMMs7. Align the FB-DIMM notch with the key in the connec

Página 19 - Text Conventions

Servicing Motherboard Components 89Note – As soon as the power cords are connected, standby power is applied.Depending on how the firmware is configur

Página 20 - Prompt Notations

90 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server takes about one minute to power off. Use the show /HOSTcommand

Página 21 - Notes on Safety

Servicing Motherboard Components 916. Run the show faulty command.If the show faulty command reports a fault with a UUID go on to Step 7.Ifshow faulty

Página 22 - Task Warning

92 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – You must disconnect the power cables from the system before performing

Página 23 - Preface xxi

Servicing Motherboard Components 93Note – If the FB-DIMM does not easily seat into the connector, it may not have thecorrect orientation. If the orien

Página 24 - Product Handling

x SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing Power Supplies 129Power Supplies Overview 129Power Supply Status LEDs 1

Página 25 - Alert Label

94 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server takes about one minute to power off. The ILOM console does not

Página 26

Servicing Motherboard Components 95FB-DIMM Configuration GuidelinesUse the guidelines described in this topic when installing, upgrading, or replacing

Página 27 - Identifying Server Components

96 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FB-DIMM Configuration ReferenceThe following figure illustrates the physical arr

Página 28

Servicing Motherboard Components 97FIGURE: FB-DIMM Slot Layout on the MotherboardFigure Legend1 Branch 3 FB-DIMM slots2 Branch 2 FB-DIMM slots3 Branch

Página 29

98 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009The following table maps FB-DIMM locations with FB-DIMM FRU names. The FRUname i

Página 30

Servicing Motherboard Components 99FIGURE: Slot Use Map for Quantities of 4, 8, and 16 FB-DIMMsFigure Legend1 4 FB-DIMM configuration2 8 FB-DIMM confi

Página 31

100 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Identify Faulty FB-DIMMs Using the show faulty Command” o

Página 32 - 3 PowerOKLED 7 Overtemp LED

Servicing Motherboard Components 1013. (SPARC Enterprise T5120 server; 8 drive-capable) Disconnect and stow the harddrive data cable.a. Route the hard

Página 33

102 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing PCIe/XAUI RisersThese topics explain how to service the riser units t

Página 34

Servicing Motherboard Components 1032. Disconnect all power cables.See “Disconnect Power Cords From the Server” on page 62.3. Attach an antistatic wri

Página 35

Contents xiServicing Power Distribution Boards 160Power Distribution Board Overview 160▼ Remove the Power Distribution Board 161▼ Install the Power Di

Página 36

104 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the PCIe/XAUI Riser (SPARC Enterprise T5220 Server)8. Loosen t

Página 37

Servicing Motherboard Components 105FIGURE: Installing the PCIe/XAUI Riser (SPARC Enterprise T5120)FIGURE: Installing the PCIe/XAUI Riser (SPARC Enter

Página 38

106 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20095. Engage the two captive Phillips screws on both sides of the removable PCI cr

Página 39

Servicing Motherboard Components 107 SPARC Enterprise T5220: PCIe filler panels are located on the riser boardassembly. Press the filler panel into t

Página 40 - Network Management Port

108 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a PCIe Card (SPARC Enterprise T5120) SPARC Enterprise T5220

Página 41 - Detecting and Managing Faults

Servicing Motherboard Components 109FIGURE: Installing a PCIe Card (SPARC Enterprise T5220)6. Insert the PCIe/XAUI card into the correct slot on the r

Página 42 - Service Processor Interfaces

110 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 200911. Connect the power supplies.See “Connect Power Cords to the Server” on page

Página 43

Servicing Motherboard Components 111PCIe and XAUI Card Reference for SPARCEnterprise T5220 ServersThe following table shows the physical PCIe/XAUI slo

Página 44 - Diagnostics Flowchart

112 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Remove a PCIe or XAUI Card” on page 106 “Install a PCIe

Página 45

Servicing Motherboard Components 113FIGURE: Battery Location (SPARC Enterprise T5120 Server Shown)Related Information “Remove a Battery” on page 113

Página 46

xii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009HDD Data Cable Routing for SAS RAID Controller Cards in Eight-DiskCapable SPARC

Página 47 - LED Overview

114 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Install a Battery1. Unpack the replacement battery.2. Press the new battery i

Página 48 - Detecting Faults With ILOM

Servicing Motherboard Components 115 Replacing a faulty SCC module -- When replacing a faulty SCC module, youmust obtain the host ID, MAC addresses,

Página 49 - ILOM Troubleshooting Overview

116 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server will not function correctly without the SCC module installed.

Página 50

Servicing Motherboard Components 1179. If the previous SCC module had modified ILOM configuration variables andyou recorded them, configure the new SC

Página 51 - Processor

118 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The firmware configuration variable settings are not stored in the SCCmo

Página 52 - Service-Related Commands

Servicing Motherboard Components 119Note – Make note of the location of expansion cards in PCIe/XAUI risers 0 and 1.10. Disconnect the motherboard-to-

Página 53

120 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Motherboard Assembly (SPARC Enterprise T5120 Server Shown)

Página 54

Servicing Motherboard Components 121FIGURE: Installing the Motherboard Assembly (SPARC Enterprise T5120 Server)3. Using the green handle and the back

Página 55

122 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20096. If you are installing a new motherboard, install the following components:a.

Página 56

123Servicing Fan ModulesThese topics explain how to service faulty fan modules. “Fan Module Overview” on page 123 “Remove a Fan Module” on page 125

Página 57 - ▼ Clear FRU Faults Manually

xiiiPrefaceThis manual provides detailed procedures that describe the removal and replacementof replaceable parts in the SPARC Enterprise™ T5120 and T

Página 58 - ▼ Create an ALOM CMT Shell

124 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Fan Module Configurations for SPARC EnterpriseT5120 Servers (4- and 8-Disk Capa

Página 59

Servicing Fan Modules 125Fan Module Status LEDsEach fan module contains a pair of LEDs, which are visible when you open the fancompartment access door

Página 60 - Detecting Faults With POST

126 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. Extend the server to the maintenance position.See “Extend the Server to the

Página 61 - Managing POST Operations

Servicing Fan Modules 127FIGURE: Removing a Fan ModuleRelated Information “Extend the Server to the Maintenance Position” on page 63▼ Install a Fan M

Página 62 - Parameter Values Description

128 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Fan Module2. Apply firm pressure to fully seat the fan mod

Página 63 - Examples of POST Management

129Servicing Power SuppliesThe topics explain how to remove and replace power supply modules. “Power Supplies Overview” on page 129 “Remove a Power

Página 64

130 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Power Supply LEDs (SPARC Enterprise T5120 Server Shown)The following ta

Página 65 - ▼ Run POST in Maximum Mode

Servicing Power Supplies 131 “Servicing Power Supply Backplanes (SPARC Enterprise T5220 Servers)” onpage 167 “Remove a Power Supply” on page 131 “I

Página 66

132 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Cable management Arm Release Mechanism4. Based on the model of your ser

Página 67 - ▼ Clear POST-Detected Faults

Servicing Power Supplies 133FIGURE: Power Supply Release Handle (SPARC Enterprise T5120 Servers)FIGURE: Power Supply Release Handle (SPARC Enterprise

Página 68 - POST Output Quick Reference

xiv SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Structure and Contents of This ManualThis manual is organized as described belo

Página 69

134 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Install a Power Supply1. Align the replacement power supply with the empty po

Página 70 - Solaris PSH Feature Overview

Servicing Power Supplies 135FIGURE: Installing a Power Supply (SPARC Enterprise T5220 Server)3. Based on the model of your server (AC or DC), apply po

Página 71

136 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20097. At the ALOM CMT sc> prompt, type the showenvironment command toverify the

Página 72

137Servicing Boards and ComponentsThese topics explain how to service field-replaceable units (FRUs) in SPARCEnterprise T5120 and T5220 servers. “Imp

Página 73 - ▼ Clear PSH-Detected Faults

138 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – Fan modules are the only chassis components that may be removed orinstal

Página 74 - Viewing Solaris OS Messages

Servicing Boards and Components 139Related Information “Remove the Hard Drive Backplane” on page 152DVD/USB Module OverviewThe DVD ROM drive and fron

Página 75 - System Recovery Commands

140 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Unplug the power cords.See “Disconnect Power Cords From the Server” on page

Página 76 - ▼ Display System Components

Servicing Boards and Components 141FIGURE: Removing the DVD/USB Module (illustrates removal from a SPARC EnterpriseT5120 server)6. Slide the DVD/USB m

Página 77 - ▼ Disable System Components

142 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing the DVD/USB Module (Illustrates installing in a SPARC Enterp

Página 78 - ▼ Enable System Components

Servicing Boards and Components 143Servicing Fan Power BoardsThese topics explain how to remove and install fan power boards. “Fan Power Board Overvi

Página 79 - ▼ Run the SunVTS Software

Preface xvRelated DocumentationThe latest versions of all the SPARC Enterprise Series manuals are available at thefollowing Web sites:Global Site(http

Página 80 - SunVTS Browser Interface

144 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Disconnect the power cables.See “Disconnect Power Cords From the Server” on

Página 81

Servicing Boards and Components 145Related Information “Install the Fan Power Board” on page 145▼ Install the Fan Power Board1. Lower the board into

Página 82

146 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Remove the Fan Power Board” on page 143Servicing the Hard

Página 83 - General Safety Information

Servicing Boards and Components 1472. Disconnect all external cables.3. Remove the server from the rack. Place the server on a hard, flat surface.See

Página 84 - Antistatic Wrist Strap Use

148 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Hard Drive Cage (Illustrating Removal From a SPARC Enterpris

Página 85 - Essential Tools

Servicing Boards and Components 149 “Remove the Hard Drive Backplane” on page 152▼ Install the Hard Drive CageBefore performing any installation step

Página 86 - Command)

150 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Hard Drive Cage (Illustrating Installation in a SPARC Ente

Página 87

Servicing Boards and Components 1513. (SPARC Enterprise T5120 server, 8 disk-capable) Remove fan FM1.4. Slide the hard drive cage back until the hard

Página 88

152 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 200914. Power on the system.See “Power On the Server Using the poweron Command” on

Página 89

Servicing Boards and Components 153 Four screws secure the backplane in the SPARC Enterprise T5220 server. See thesecond figure below.FIGURE: Removin

Página 90 - Slide Release Latches

xvi SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009SPARC Enterprise T5120 andT5220 Servers Installation GuideDetailed rackmounting

Página 91

154 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Hard Drive Backplane (Illustrating removal from a SPARCEnter

Página 92 - Accessing Internal Components

Servicing Boards and Components 155FIGURE: Installing a Hard Drive Backplane in a SPARC Enterprise T5120 Server

Página 93 - ▼ Remove the Top Cover

156 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Hard Drive Backplane in a SPARC Enterprise T5220 Server3.

Página 94

Servicing Boards and Components 157Front Control Panel Light Pipe AssembliesOverviewThe front control panel light pipe assemblies are mounted on each

Página 95 - Servicing Hard Drives

158 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Front Control Panel Light Pipe Assembly From a SPARCEnterp

Página 96 - Hard Drive LEDs

Servicing Boards and Components 159FIGURE: Installing a Front Control Panel Light Pipe Assembly in a SPARC EnterpriseT5220 Server3. Secure the light p

Página 97 - ▼ Remove a Hard Drive

160 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing Power Distribution BoardsThe following topics explain how to remove a

Página 98

Servicing Boards and Components 161▼ Remove the Power Distribution Board1. Note the chassis serial number and part number.The chassis serial number an

Página 99 - ▼ Install a Hard Drive

162 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Power Distribution Board From a SPARC Enterprise T5220 Serve

Página 100

Servicing Boards and Components 163FIGURE: Removing the Power Distribution Board From a SPARC Enterprise T5120 Server8. Grasp the bus bar and pull the

Página 101 - Servicing Hard Drives 75

Preface xviiNote – Product Notes are available on the website only. Please check for the recentupdate on your product.UNIX CommandsThis document might

Página 102 - Related Information

164 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Power Distribution Board in a SPARC Enterprise T5120 Serve

Página 103 - Configuration Reference

Servicing Boards and Components 165FIGURE: Installing a Power Distribution Board in a SPARC Enterprise T5220 Server5. (SPARC Enterprise T5220 server)

Página 104 - Eight-Drive Capable Backplane

166 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Power Supply in a SPARC Enterprise T5120 Server8. Install

Página 105

Servicing Boards and Components 167Caution – When performing the following steps, use special care to enter the correctnumbers. Once the power distrib

Página 106

168 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Supply Backplane OverviewThe power supply backplane carries 12V power fro

Página 107 - Servicing FB-DIMMs

Servicing Boards and Components 169FIGURE: Removing a Power Supply From a SPARC Enterprise T5220 Server3. Remove the power distribution board.See “Rem

Página 108

170 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Install the Power Supply Backplane” on page 170▼ Install

Página 109 - Fault Locator Button

Servicing Boards and Components 171FIGURE: Installing a Power Supply (Illustrating Installation of a Power Supply in aSPARC Enterprise T5220 Server)5.

Página 110

172 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Paddle Card OverviewThe paddle card serves as the interconnect between the powe

Página 111 - ▼ Remove FB-DIMMs

Servicing Boards and Components 1736. Tilt the paddle card away from the side of the chassis and lift the paddle cardup and out of the system.7. Place

Página 113

xviii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Prompt NotationsThe following prompt notations are used in this manual.Conven

Página 114 - Installing FB-DIMMs

174 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Página 115 - FB-DIMMs

175Returning the Server to OperationThese topics explain how to return SPARC Enterprise T5120 and T5220 servers tooperation after you have performed s

Página 116

176 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing the Top CoverNote – If an emergency shutdown occurred when t

Página 117 - Additional FB-DIMMs

Returning the Server to Operation 177FIGURE: Returning the Server to the Rack2. Slide the server into the rack until the brackets lock into place.The

Página 118

178 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Release Tabs on the Rail2. While pushing on the release tabs, slowly pu

Página 119 - Stopping /SYS

Returning the Server to Operation 179Note – As soon as the power cords are connected, standby power is applied.Depending on how the firmware is config

Página 120

180 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Power On the Server Using the FrontPanel Power Button● Use a pointed object,

Página 121

181Identifying FRUs in SPARCEnterprise T5120 ServersThese topics identify and illustrate Field Replaceable Units (FRUs) contained inSPARC Enterprise T

Página 122

182 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Motherboard Components in T5120ServersFIGURE: Motherboard Components (SPARC Ent

Página 123 - Figure Legend

Identifying FRUs in SPARC Enterprise T5120 Servers 183The following table identifies the components located on the motherboard and pointsto instructio

Página 124 - FB-DIMM Installation Map

Preface xixCaution – This indicates that hazardous voltages are present. To reduce the risk ofelectric shock and danger to personal health, follow the

Página 125 - 3 16 FB-DIMM configuration

184 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009I/O Components in SPARC EnterpriseT5120 ServersFIGURE: I/O Components (SPARC En

Página 126 - Servicing the Air Duct

Identifying FRUs in SPARC Enterprise T5120 Servers 185The following table identifies the I/O components in the server and points toinstructions for se

Página 127 - ▼ Install the Air Duct

186 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Distribution/Fan ModuleComponents in SPARC Enterprise T5120ServersFIGURE:

Página 128 - Servicing PCIe/XAUI Risers

Identifying FRUs in SPARC Enterprise T5120 Servers 187The following table identifies the power distribution and fan module components inthe server and

Página 129

188 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Internal Cables for Onboard SASController Cards in SPARC EnterpriseT5120 Server

Página 130 - ▼ Install a PCIe/XAUI Riser

Identifying FRUs in SPARC Enterprise T5120 Servers 189FIGURE: HDD Cable from Onboard SAS to HDD Backplane (4-Disk Capable SPARCEnterprise T5120 Server

Página 131

190 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Internal Cables for the Onboard SAS Controller Card (Eight-Disk Capable

Página 132 - ▼ Remove a PCIe or XAUI Card

Identifying FRUs in SPARC Enterprise T5120 Servers 191HDD Data Cable Routing for SAS RAIDController Cards in Four-Disk CapableSPARC Enterprise T5120 S

Página 133 - ▼ Install a PCIe or XAUI Card

192 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Hard Drive Data Cable Routing for SAS RAID Controller Card in Four-Disk

Página 134

Identifying FRUs in SPARC Enterprise T5120 Servers 193HDD Data Cable Routing for SAS RAIDController Cards in Eight-Disk CapableSPARC Enterprise T5120

Página 135

xx SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – This indicates that hazardous voltages are present. To reduce the risk

Página 136

194 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Hard Drive Data Cable Routing for SAS RAID Controller Card in Eight-Dis

Página 137 - Enterprise T5220 Servers

195Identifying FRUs in SPARCEnterprise T5220 ServersThese topics identify and illustrate Field Replaceable Units (FRUs) contained inSPARC Enterprise T

Página 138 - Servicing the Battery

196 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Motherboard Components in T5220ServersFIGURE: Motherboard Components in SPARC E

Página 139 - ▼ Remove a Battery

Identifying FRUs in SPARC Enterprise T5220 Servers 197The following table identifies the components located on the motherboard and pointsto instructio

Página 140 - Servicing the SCC Module

198 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009I/O Components in SPARC EnterpriseT5220 ServersFIGURE: I/O Components (SPARC En

Página 141 - ▼ Remove a Faulty SCC Module

Identifying FRUs in SPARC Enterprise T5220 Servers 199The following table identifies the I/O components in the server and points toinstructions for se

Página 142 - ▼ Install a New SCC Module

200 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Distribution/Fan ModuleComponents in SPARC Enterprise T5220ServersFIGURE:

Página 143

Identifying FRUs in SPARC Enterprise T5220 Servers 201The following table identifies the power distribution and fan module components inthe server and

Página 144

202 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Internal Cables for Onboard SASController Cards in SPARC EnterpriseT5220 Server

Página 145 - ■ SCC Module

Identifying FRUs in SPARC Enterprise T5220 Servers 203FIGURE: Internal Cables for Onboard SAS Controller Cards (Eight-Disk Capable SPARC Enterprise T5

Página 146

Preface xxiCaution – This indicates that surfaces are hot and might cause personal injury iftouched. Avoid contact.Task WarningMaintenance Extremely h

Página 147

204 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Internal Cables for the Onboard SAS Controller Card (Eight-Disk Capable

Página 148

Identifying FRUs in SPARC Enterprise T5220 Servers 205FIGURE: Internal Cables for Onboard SAS Controller Cards (Sixteen-Disk Capable SPARCEnterprise T

Página 149 - Servicing Fan Modules

206 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009HDD Data Cable Routing for SAS RAIDController Cards in SPARC EnterpriseT5220 Se

Página 150

Identifying FRUs in SPARC Enterprise T5220 Servers 207FIGURE: HDD Data Cable Routing for SAS RAID Controller Cards in Eight- orSixteen-Disk Capable SP

Página 151 - ▼ Remove a Fan Module

208 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Página 152

209IndexAabout, 16AC Present (power supply LED), 19, 135airflow, blocked, 20antistatic wrist strap, 58ASR blacklist, 50asrkeys (system components), 51B

Página 153 - ▼ Install a Fan Module

210 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009fan power boardFRU name, 187, 201Fault (fan module LED), 128Fault (hard drive L

Página 154

Index 211power supplyabout, 129AC Present LED, 19, 135Fault LED, 21, 131FRU name, 136, 187, 201Power Supply Fault (system LED)interpreting to diagnose

Página 155 - Servicing Power Supplies

212 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009removing, 67topic guidelines, 1, 15, 57, 69, 81, 123, 129, 137, 175,181, 195tro

Página 157 - ▼ Remove a Power Supply

xxii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Product HandlingMaintenanceWarning – Certain tasks in this manual should only

Página 159 - Servicing Power Supplies 133

Preface xxiiiAlert LabelThe following is a label attached to this product: Never peel off the label. The following label provides information to the

Página 160 - ▼ Install a Power Supply

xxiv SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Fujitsu Welcomes Your CommentsIf you have any comments or requests regarding t

Página 161 - Servicing Power Supplies 135

1Identifying Server ComponentsThese topics identify key components of the SPARC Enterprise T5120 and T5220servers, including major boards and internal

Página 162 - /SYS/PS0

2 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Infrastructure Boards in SPARCEnterprise T5120 ServersSPARC Enterprise T5120 serv

Página 163 - Important Safety Instructions

Identifying Server Components 3 “Identifying FRUs in SPARC Enterprise T5120 Servers” on page 181 “Identifying FRUs in SPARC Enterprise T5220 Servers

Página 164 - Servicing DVD/USB Modules

SPARC EnterpriseTMT5120 and T5220 ServersService ManualPart No. 875-4194-13July 2009, Revision AManual Code C120-E463-04EN

Página 165 - ▼ Remove the DVD/USB Module

4 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Infrastructure Boards in SPARC Enterprise T5120 Servers” on

Página 166

Identifying Server Components 5Internal System Cables for SPARCEnterprise T5220 ServersThe following table identifies the internal system cables used

Página 167 - ▼ Install the DVD/USB Module

6 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Front Panel Controls and Indicators on SPARC Enterprise T5120 ServersFigu

Página 168

Identifying Server Components 7The following table provides descriptions of these controls and indicators.TABLE: Front Panel Controls and Indicators (

Página 169 - Servicing Fan Power Boards

8 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “LED Overview” on page 21Rear Panel Components and Indicator

Página 170 - T5120 server)

Identifying Server Components 9The following table provides descriptions of the LEDs located on the rear panel.Related Information “LED Overview” on

Página 171 - ▼ Install the Fan Power Board

10 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Front Panel Controls and Indicators on SPARC Enterprise T5220 ServersFig

Página 172 - Servicing the Hard Drive Cage

Identifying Server Components 11The following table provides descriptions of these controls and indicators.TABLE: Front Panel Controls and Indicators

Página 173

12 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “LED Overview” on page 21Rear Panel Components and Indicato

Página 174

Identifying Server Components 13The following table provides descriptions of the LEDs located on the rear panel.Related Information “LED Overview” on

Página 175 - ▼ Install the Hard Drive Cage

PleaseRecycleCopyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.FUJITSU LIMITED p

Página 176 - T5220 Server)

14 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Status LEDs for Ethernet Ports andNetwork Management PortThe following table des

Página 177

15Detecting and Managing FaultsThese topics explain how to use various diagnostic tools to monitor server status andtroubleshoot faults in the server.

Página 178 - Hard Drive Backplane Overview

16 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009 Power-on self-test (POST) – POST performs diagnostics on system componentswhen

Página 179 - Enterprise T5120 server)

Detecting and Managing Faults 17Multiple service processor accounts can be active concurrently. A user can issueILOM shell commands while logged in un

Página 180

18 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Diagnostics Flowchart

Página 181

Detecting and Managing Faults 19The following table provides brief descriptions of the troubleshooting actions shownin the flowchart. It also provides

Página 182 - Assemblies

20 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Check if the fault isenvironmental.(Flowchart item 6)Determine if the fault is a

Página 183 - Overview

Detecting and Managing Faults 21LED OverviewThe server provides the following groups of LEDs: Front panel system LEDs Rear panel system LEDs Hard d

Página 184

22 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Detecting Faults With ILOMThese topics explain how to use ILOM, the service proc

Página 185

Detecting and Managing Faults 23ILOM Troubleshooting OverviewILOM enables you to remotely run diagnostics such as power-on self-test (POST),that would

Página 186

Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.Entrée et revue tecnical

Página 187

24 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – No ILOM command is needed to manually repair an environmental fault.The s

Página 188

Detecting and Managing Faults 25How to Switch From the System Console to the ServiceProcessorThe following example shows the character sequence (hash-

Página 189

26 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Service-Related ILOM Command SummaryThe following table describes the ILOM shell

Página 190

Detecting and Managing Faults 27set /HOST/bootmode property=value[where property is state, config,or script]bootmode [normal] [reset_nvram][config=con

Página 191

28 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009set /SYS/LOCATE value=value[Fast_blink | Off]setlocator value[on | off]Turns the

Página 192

Detecting and Managing Faults 29Related Information “Managing Components With Automatic System Recovery Commands” onpage 50Faults Displayed by show f

Página 193

30 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Example of show faulty Output When No Fault isPresentExample of show faulty Outp

Página 194

Detecting and Managing Faults 31PSH TechnologyRelated Information “Clear FRU Faults Manually” on page 31 “Display FRU Information With the show Comm

Página 195

32 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Display FRU Information With the showCommand● At the -> prompt, enter the s

Página 196

Detecting and Managing Faults 33The service processor sends email alerts to all ALOM CMT users that are logged in.It also enters the event in the ILOM

Página 198 - ▼ Remove the Paddle Card

34 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20093. Log out of the root account after you have finished creating the new account.

Página 199 - ▼ Install the Paddle Card

Detecting and Managing Faults 35POST OverviewPower-on self-test (POST) is a group of PROM-based tests that run when the server ispowered on or when it

Página 200

36 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The value of keyswitch_state must be normal when individual POSTparameter

Página 201 - ▼ Install the Top Cover

Detecting and Managing Faults 37FIGURE: Flowchart of ILOM Properties Used to Manage POST OperationsExamples of POST ManagementThis topic shows example

Página 202

38 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – When you change individual POST parameter values, thekeyswitch_state valu

Página 203 - Position

Detecting and Managing Faults 39▼ Run POST in Maximum ModePOST can be helpful when used as a first-stage diagnostic tool. When a fault’ssymptoms are u

Página 204

40 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20094. If POST detects a faulty device, information about the device will be passed

Página 205

Detecting and Managing Faults 41Note – The system can boot and run using memory that was not disabled.Related Information “Clear POST-Detected Faults

Página 206 - Panel Power Button

42 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Clear the fault by setting the FRU’s component_state property to Enabled.This

Página 207 - Enterprise T5120 Servers

Detecting and Managing Faults 43The following example. POST reports a memory error at FB-DIMM location/SYS/MB/CMP0/BR1/CH0/D0. The error was detected

Página 208

vContentsPreface xiiiIdentifying Server Components 1Infrastructure Boards in SPARC Enterprise T5120 Servers 2Infrastructure Boards in SPARC Enterprise

Página 209

44 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Solaris PSH Feature OverviewThe Solaris OS uses the Fault Manager daemon, fmd(1M

Página 210 - T5120 Servers

Detecting and Managing Faults 45PSH-detected faults also cause the Service Required LED to be turned on.Use the ILOM show faulty command to view summa

Página 211

46 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. Check the event log using the fmdump command with -v for verbose output.In th

Página 212 - Power Distribution/Fan Module

Detecting and Managing Faults 473. Follow the suggested actions to repair the fault.▼ Clear PSH-Detected FaultsWhen the Solaris PSH facility detects f

Página 213

48 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20093. Use the clear_fault_action property of the FRU to clear the fault from theser

Página 214

Detecting and Managing Faults 49The /var/adm directory contains several message files. The most recent messagesare in the /var/adm/messages file. Afte

Página 215 - Enterprise T5120 Server)

50 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009The database that contains the list of disabled components is referred to as the

Página 216

Detecting and Managing Faults 51● At the -> prompt, enter the show components command.In the following example, PCIE3 is shown as disabled.Related

Página 217

52 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – In the ILOM shell there is no notification when the system is actuallypow

Página 218 - Servers

Detecting and Managing Faults 53Detecting Faults Using SunVTS SoftwareThis topic explains in general terms how to use SunVTS software to exercise syst

Página 219

vi SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009How to Switch From the System Console to the Service Processor 25How to Switch F

Página 220

54 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: SunVTS Browser Interface4. (Optional) Select the test category you want

Página 221

Detecting and Managing Faults 556. Click the Start button to start the test process. Status and error messages appearin the test messages area located

Página 222

56 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Página 223

57Preparing to Service the SystemThese topics describe how to prepare the SPARC Enterprise T5120 and T5220 serversfor servicing. “General Safety Info

Página 224 - T5220 Servers

58 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – There is a risk of personal injury or equipment damage. To avoidperson

Página 225

Preparing to Service the System 59Antistatic MatPlace ESD-sensitive components such as motherboards, memory, and other PCBs onan antistatic mat.Essent

Página 226

60 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Removing Power From the SystemThese topics describe different methods for removi

Página 227

Preparing to Service the System 61Note – Additional information about powering off the server is located in the SPARCEnterprise T5120 and T5220 Server

Página 228

62 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Power Off the Server (Power Button - Graceful)● Press and release the Power bu

Página 229 - Servers)

Preparing to Service the System 63▼ Extend the Server to the Maintenance PositionThe following components can be serviced with the server in the maint

Página 230

Contents viiViewing Solaris OS Messages 48▼ Check the Message Buffer 49▼ View the System Message Log Files 49Managing Components With Automatic System

Página 231 - Enterprise T5220 Servers)

64 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Slide Release Latches4. While squeezing the slide release latches, slowl

Página 232

Preparing to Service the System 651. Disconnect all the cables and power cords from the server.2. Extend the server to the maintenance position.See “P

Página 233

66 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20094. From the front of the server, pull the release tabs forward and pull the serv

Página 234

Preparing to Service the System 67▼ Perform Electrostatic Discharge PreventionMeasuresMany components housed within the chassis can be damaged by elec

Página 235

68 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Top Cover3. Remove the top cover.Lift up and remove the cov

Página 236

69Servicing Hard DrivesThese topics explain how to remove and install hard drives in SPARC EnterpriseT5120 and T5220 servers. “Hard Drive Servicing O

Página 237 - Index 211

70 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009If either of these conditions exist, you must power off the server before replac

Página 238

Servicing Hard Drives 71The following table explains how to interpret the hard drive status LEDs.Note – The front and rear panel Service Required LEDs

Página 239

72 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. At the Solaris prompt, type the cfgadm -al command. This will list all drives

Página 240

Servicing Hard Drives 73FIGURE: Locating the Hard Drive Release Button and LatchCaution – The latch is not an ejector. Do not bend the latch too far t