Página 2

viii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084.4.2 System Power Off 4–104.4.3 Domain Power On 4–114.4.4 Domain Power Off 4–1

Página 3 - Servers XSCF User’s Guide

2-44 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the setdate (8) command to set the time.<Example 1> Set the current

Página 4

Chapter 2 Setting Up XSCF 2-452. Use the showntp (8) command to check synchronization and display the status.XSCF> showntp –l remote

Página 5

2-46 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Changing Stratum Value for XSCF Command operation1. Use the showntp (8) command

Página 6

XSCF> poweroff -aDomainIDs to power off:00,01,02,03Continue? [y|n] :y00 : Powering off01 : Powering off02 : Powering off03 : Powering off*Note*This

Página 7 - Contents

2-48 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20085. Use the poweron (8) command to turn on power to all domains.XSCF> poweron

Página 8

Chapter 2 Setting Up XSCF 2-49SSH ClientIn this system, you can use the following SSH clients. Solaris Secure Shell OpenSSH PuTTY UTF-8 TeraTer

Página 9 - Contents vii

2-50 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – To enable the SSH, to generate the host key, and to disable the telnet, t

Página 10

<Example 1> Display SSH settingsXSCF> showsshSSH status: enabledRSA key:: DSA key::<Example 2> Display telnet settingsXSCF> showteln

Página 11

2-52 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Specifying an SSH Host Key Command operation1. Use the showssh (8) command to d

Página 12

Chapter 2 Setting Up XSCF 2-53 After the XSCF reset, the XSCF session is disconnected. Please log in again to the XSCF.Specifying the Timeout Peri

Página 13 - Contents xi

Contents ix5.6 View and Archive the XSCF Logs 5–155.7 User Management and Security Commands 5–155.8 Use the XSCF Other Commands 5–165.9 View XSCF S

Página 14

XSCF> setssh -c addpubkey -u efghPlease input a public key:ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzFh95SohrDgpnN7zFCJCVNy+jaZPTjNDxcid/QGbihYDCBttI415

Página 15

Chapter 2 Setting Up XSCF 2-55TABLE 2-10 lists a term used in https administration.TABLE 2-10 https Administration Term Term DescriptionXSCF Web

Página 16

2-56 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081. Construct the self CA for the XSCF.2. Create a web server private key for the

Página 17

Chapter 2 Setting Up XSCF 2-57Note – To enable the https, an XSCF reset is required. Please reset the XSCF using by rebootxscf (8) command. After t

Página 18

<Example 1> Enable https.XSCF> sethttps -c enableContinue? [y|n] : yPlease reset the XSCF by rebootxscf to apply the https settings.<Examp

Página 19

XSCF> showhttpsHTTPS status: disabledServer key: installed in Jul 11 06:33:25 UTC 2006CA key: installed in Jul 11 06:33:21 UTC 2006CA cert: install

Página 20

2-60 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Creating a Web Server Certificate by Constructing the Self CA Command operation

Página 21 - Preface xix

Chapter 2 Setting Up XSCF 2-612.2.7 Audit AdministrationAudit administration is used to specify logging of access details, such as which users logg

Página 22 - Glossary

2-62 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 2-13 lists the setting items and the corresponding shell commands.Audit tr

Página 23

Chapter 2 Setting Up XSCF 2-63Note – (1) If audit is disabled, writing to the audit trail is stopped, all requests to the log file transfer to the

Página 24 - Documentation

x SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20088.1.12 Frequently Asked Questions 8–188.2 Collecting XSCF Logs 8–198.2.1 Log Types

Página 25 - Preface xxiii

2-64 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – (3) If an audit trail becomes full while suspend is specified, XSCF Shell

Página 26

Chapter 2 Setting Up XSCF 2-65Enabling or Disabling Audit, Transferring a Log File, and Deleting Audit Data Command operation1. Use the showaudit

Página 27 - Documents

2-66 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Specifying the Audit Policy Command operation1. Use the showaudit (8) command t

Página 28 - Text Conventions

XSCF> showaudit allAuditing: enabledAudit space used: 13713 (bytes)Audit space free: 4180591 (bytes)Records dropped: 0Poli

Página 29 - Prompt Notations

2-68 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082.2.8 Log Archiving AdministrationThis section explains how to set the log archi

Página 30 - Limitations and Notes

Chapter 2 Setting Up XSCF 2-69Note – For the types of logs that can be saved, see Chapter 8.Note – When you set neither a defined value nor a value

Página 31 - Preface xxix

2-70 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Specifying a Host Name, Directory Name, Login User Name and Password for the Tar

Página 32 - Reader's Comment Form

Chapter 2 Setting Up XSCF 2-714. Use the showarchiving (8) command to confirm the settings.XSCF> showarchiving*** Archiving Configuration ***Ar

Página 33 - BUSINESS REPLY MAIL

2-72 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Setting Capacity Limits for the Log Archiving Function Command operation1. Use

Página 34

Chapter 2 Setting Up XSCF 2-73Displaying Log Archiving Error Information Command operation● Use the showarchiving (8) command to display details

Página 35 - XSCF Overview

Contents xiB.4.3 Console Log B–9B.4.4 Panic Log B–9B.4.5 IPL Log B–10B.5 Audit Log B–10C. XSCF MIB C–1C.1 MIB Object Identifiers C–1C.2 Standard

Página 36 - External Interfaces

2-74 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 2-17 lists settings and the corresponding shell commands.VAC M Abbreviatio

Página 37 - XSCF Unit (Front)

Chapter 2 Setting Up XSCF 2-75SNMPv1/ SNMPv2c communication Enables/disables SNMPv1 and SNMPv2c communication.setsnmp The community string used to

Página 38 - Link Speed LED

2-76 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – (1) A user name, authentication password, and encryption password that ar

Página 39 - READY LED

<Example> Display of the status when no management information has been setXSCF> showsnmpAgent Status: DisabledAgent port: 161

Página 40

2-78 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Setting SNMPv3 Trap Command operation1. Use the showsnmp (8) command to displa

Página 41 - 1.2 XSCF Functions

Chapter 2 Setting Up XSCF 2-793. Confirm the SNMPv3 trap settings.XSCF> showsnmp Agent Status: EnabledAgent Port: 161System Locati

Página 42 - Security

2-80 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Enabling/Disabling the SNMPv1 and SNMPv2c Communication Command operation1. U

Página 43 - ■ When power is restored:

Chapter 2 Setting Up XSCF 2-81Disabling Traps to the Target Host of SNMPv1/SNMPv2c Command operation1. Use the showsnmp (8) command to display S

Página 44

2-82 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the setsnmpusm (8) command to set USM management information.<Example

Página 45 - Firmware Update Function

Chapter 2 Setting Up XSCF 2-831. Use the showsnmpvacm (8) command to display VACM management information.XSCF> showsnmpvacmGroups:Groupname

Página 46

xii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 47 - XSCF-LAN Ethernet Connection

2-84 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082.2.10 Mail AdministrationThe mail report function is used to send an email to t

Página 48

Chapter 2 Setting Up XSCF 2-85Specifying the Host Name, Port Number, and Reply Address of the SMTP Server Command operation1. Use the showsmtp (8

Página 49 - XSCF-LAN Redundancy

2-86 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20083. Check the SMTP server setting information.XSCF> showsmtpMail Server: 192.1

Página 50

Chapter 2 Setting Up XSCF 2-872.2.11 Domain ConfigurationDomain Configuration logically assigns (by partitioning) multiple system boards (XSBs) mou

Página 51

2-88 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Uni-XSB One of the division types for a PSB to be configured. Uni-XSB is a name

Página 52 - 1.4 XSCF User Interfaces

Chapter 2 Setting Up XSCF 2-89Note – DR: Abbreviation for Dynamic Reconfiguration. This function dynamically adds a system board to a domain or del

Página 53

TABLE 2-20 Number of Domains and XSBs for Each System SystemRange of Domain IDMaximum Number of XSBsMemory Mirror (Note)High-end system with expansio

Página 54 - XSCF LAN

Chapter 2 Setting Up XSCF 2-91Note – The PSB number is same as the CMU / I/O unit slot number.Note – If a PSB has one XSB number, the Uni-XSB confi

Página 55

2-92 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – FRU; Field-Replaceable Unit.Note – One domain can use up to 16 LSBs. The

Página 56

Chapter 2 Setting Up XSCF 2-93Note – The result of the initial diagnosis by testsb (8) command is displayed in specified PSB. For details about the

Página 57 - Setting Up XSCF

xiiiFiguresFIGURE 1-1 Outline Drawing of the XSCF Unit Front Panel (An Example of the Midrange Systems) 1–3FIGURE 1-2 Outline Drawing of Front Panels

Página 58 - About Setup Flow

2-94 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 2-2 Domain Component HardwareCMU/MBUIOUPSBI/O deviceI/O deviceCPU CPUMem

Página 59 - ■ Default password:

Chapter 2 Setting Up XSCF 2-95FIGURE 2-3 XSCF-Domain Correlation DiagramDomain modulesXSCF modulesXSCF-Domain networkDSCP InterfaceXSCF-Domain Com

Página 60 - Administration” on page 2-29)

2-96 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 2-4 XSB Configuration Diagram (Uni-XSB) (In the Midrange Systems)CMU IOU

Página 61

Chapter 2 Setting Up XSCF 2-97FIGURE 2-5 XSB Configuration Diagram (Quad-XSB) (In the Midrange Systems)CMU IOUXSB#00-2XSB#00-3XSB#00-0XSB#00-1XSB#

Página 62

2-98 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 2-6 XSB Configuration Diagram (Uni-XSB) (In the High-End Systems)IOU#nCM

Página 63 - Connecting? [yes

Chapter 2 Setting Up XSCF 2-99FIGURE 2-7 XSB Configuration Diagram (Quad-XSB) (In the High-End Systems)IOU#nCMU#nWhen PSB#n is Quad-XSB typeXSB#xx

Página 64

2-100 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – For the procedure for installing, removing, or replacing a system board

Página 65

Chapter 2 Setting Up XSCF 2-101Note – For details on using DR functions, see the Dynamic Reconfiguration User’s Guide.Delete from domainDeletes an

Página 66

2-102 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Displaying the XSB Status By referring to the XSB status of a domain, the user

Página 67

<Example> Display DCL information on domain ID 2.XSCF> showdcl -v -d 2 DID LSB XSB Status No-Mem No-IO Float Cfg-policy02

Página 68

xiv SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 FIGURE 3-7 Example of LAN Port Connections Not Made Redundant 3–17FIGURE 3-8 Exam

Página 69 - ■ Log in

XSCF> showdcl -va DID LSB XSB System No-Mem No-IO Float Cfg-policy02 Powered Off System

Página 70

XSCF> showfru –a sbDevice Location XSB Mode Memory Mirror Modesb 00 Uni nosb 01 Quad

Página 71 - 2.2.1 Network Configuration

2-106 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20083. Use the addboard (8) command to add an XSB and use the showboards (8) comman

Página 72 - Network Configuration

XSCF> showboards –vaXSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD---- - -------- ----------- ---- ---- ---- ------- -------- ----

Página 73 - TABLE 2-1)

2-108 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Deleting a System Board From a Domain Command operation1. Use the showdevices

Página 74

Chapter 2 Setting Up XSCF 2-1092. Use the showboards (8) command to display XSB status information.XSCF> showboards –vaXSB R DID(LSB) Assignmen

Página 75 - End Systems)

2-110 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – When you delete the system board, please confirm the domain status, the

Página 76 - FIGURE 2-1)

Chapter 2 Setting Up XSCF 2-1113. Use the showdcl (8) command to confirm the DCL information.XSCF> showdcl –aDID LSB XSB Status01

Página 77 - FIGURE 2-1). Also, both ISN

2-112 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20086. Use the showboards (8) command to discplay the XSB status again.XSCF> sho

Página 78

Chapter 2 Setting Up XSCF 2-1132.2.12 System Board ConfigurationSystem board configuration settings are used to specify XSB division information fo

Página 79

xvTablesTABLE 1-1 XSCF-LAN Operation Examples 1 1–14TABLE 1-2 XSCF-LAN Operation Examples 2 1–14TABLE 1-3 XSCF-LAN Operation Examples 3 1–14TABLE 1

Página 80

2-114 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – Memory mirroring requires twice the amount of memory domain used for ope

Página 81

Chapter 2 Setting Up XSCF 2-115Setting the Memory Mirror Mode for a PSB Command operation1. Use the showfru (8) command to display PSB memory mirr

Página 82

2-116 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084. Use the testsb (8) command to check the PSB, then check the results by using

Página 83 - Making XSCF DNS Settings

Chapter 2 Setting Up XSCF 2-117TABLE 2-27 lists terms used in domain mode configuration.TABLE 2-27 Domain Mode Configuration Terms Term Descriptio

Página 84

2-118 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 2-28 lists setting items and the corresponding shell commands.TABLE 2-28

Página 85

Chapter 2 Setting Up XSCF 2-119SPARC64 VI and SPARC64 VII Processors and CPU Operational ModesNote – This section applies only to SPARC Enterprise

Página 86 - User Account Administration

2-120 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008A mix of SPARC64 VI and SPARC64 VII processors can be mounted on a single CMU,

Página 87

Chapter 2 Setting Up XSCF 2-121Note – Change the cpumode from auto to compatible for any domain that has or is expected to have a mix of processor

Página 88 - TABLE 2-4.)

<Example> Specify the maximum initial hardware diagnostic level for domain ID 0.XSCF> setdomainmode -d 0 -m diag=maxDiagnostic Level :min

Página 89 - Specifying a User Privilege

Chapter 2 Setting Up XSCF 2-1232. Use the setdomainmode (8) command to specify host watchdog and break signal suppression.<Example> Enable Ho

Página 90 - Specifying a Password Policy

xvi SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 TABLE 2-15 Log Archiving Administration 2–68TABLE 2-16 SNMP Administration Terms

Página 91 - 2.2.3 LDAP Administration

2-124 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Enabling or Disabling the Automatic Boot Function Command operation1. Use the

Página 92 - LDAP Administration

Chapter 2 Setting Up XSCF 2-125Specifying the CPU Operational Mode Command operation1. Power off the domain.2. Use the showdomainmode (8) command

Página 93

2-126 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082.2.14 Locale AdministrationLocale administration is used to set the XSCF Shell

Página 94

Chapter 2 Setting Up XSCF 2-1272.2.15 Altitude AdministrationThis section explains the altitude settings. The server changes the system monitoring

Página 95

2-128 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082.2.16 DVD Drive/Tape Drive Unit AdministrationDVD drive/tape drive unit config

Página 96

Chapter 2 Setting Up XSCF 2-129TABLE 2-32 lists the settings and the corresponding shell commands.TABLE 2-32 DVD Drive/Tape Drive Unit Configurati

Página 97 - Setting Time and Date

2-130 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Changing the DVD Drive/Tape Drive Unit Settings Command operation1. Use the cf

Página 98 - Specifying a Time Zone

Chapter 2 Setting Up XSCF 2-1312.2.17 COD AdministrationCOD administration is used to set COD license information for storage in the COD license da

Página 99 - Setting the XSCF Time

2-132 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – (1) A license key must be acquired in advance. To acquire the license, c

Página 100 - Configuring an NTP Server

Chapter 2 Setting Up XSCF 2-1332. Use the showcodusage (8) command to display the use status of COD licenses.<Example> Display the use statu

Página 101

Tables xviiTABLE 9-1 XSCF Web Pages 9–2TABLE 9-2 Supported Browsers 9–6TABLE 9-3 System Status Display 9–11TABLE 9-4 Domain Status Display 9–11TAB

Página 102 - ■ Command operation

<Example 1> Display COD board information.XSCF> showboards -vaXSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD---- - --------

Página 103 - XSCF>

3-1CHAPTER3Connecting to the XSCF and the ServerThis chapter describes how to connect consoles and terminals to XSCF in order to use the software, and

Página 104 - Term Description

3-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20083.1.1 Terminal Operating Modes for Connection to XSCFThe FIGURE 3-1 shows the ter

Página 105 - SSH Client

Chapter 3 Connecting to the XSCF and the Server 3-3(8) command. After that, you can use the domain console (OS console) (see Note below). You can r

Página 106

TABLE 3-1 Types of Terminals Connected With XSCF Port Terminal Type Port Number, CableXSCF-LAN port(2 ports per XSCF Unit)[10/100 Mbps]• XSCF Shell t

Página 107

Chapter 3 Connecting to the XSCF and the Server 3-5Note – A maximum of 20 users can be connected to the XSCF at the same time in the midrange syste

Página 108 - Specifying an SSH Host Key

3-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 3-3 lists the port numbers used for the DSCP Link and the functions. When y

Página 109

Chapter 3 Connecting to the XSCF and the Server 3-7FIGURE 3-2 shows an example with settings.FIGURE 3-2 Example of Terminal Software SettingsNote

Página 110 - 2.2.6 Https Administration

3-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008d. The XSCF Shell can now be used. Connecting the domain console (OS console)a.

Página 111 - CA and Procedures

Chapter 3 Connecting to the XSCF and the Server 3-9b. Follow Step a to Step d in the above “Connecting the XSCF Shell terminal.”c. Perform the cons

Página 113 - Enabling or Disabling Https

xviii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 114 - Intranet

3-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008c. Confirm that the XSCF Shell prompt (XSCF>) is displayed.d. The XSCF Shel

Página 115

Chapter 3 Connecting to the XSCF and the Server 3-11Note – For details on types of the escape character, see the man page or the XSCF Reference Man

Página 116

3-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 3-4 shows the intranet connection.FIGURE 3-4 Intranet Connection (In a H

Página 117

Chapter 3 Connecting to the XSCF and the Server 3-13FIGURE 3-5 shows the connection via an external network.FIGURE 3-5 Connection of External Inte

Página 118 - Audit Administration

3-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008XSCF Connection via a Serial PortEstablish an XSCF connection via a serial port.

Página 119 - Command Remarks

Chapter 3 Connecting to the XSCF and the Server 3-15In the example of the configuration shown in FIGURE 3-6, if errors occur in either of the two L

Página 120

3-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 3-6 Example of LAN Port Connections Made RedundantDirect attach portfor

Página 121 - Audit Data

Chapter 3 Connecting to the XSCF and the Server 3-17FIGURE 3-7 Example of LAN Port Connections Not Made RedundantPort from XSCFU#0Port from XSCFU#

Página 122 - Specifying the Audit Policy

3-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 3-8 Example of a Connection With One LAN PortPort from XSCFU#0Port from

Página 123 - Displaying the Audit Logs

4-1CHAPTER4Operation of the ServerThis chapter mainly describes operation of the server hardware.4.1 Display Server Hardware EnvironmentThis section d

Página 124 - Log Archiving Administration

Preface xixPrefaceThis manual describes the system monitor and control facility (eXtended System Control Facility, or XSCF, hereafter) used to control

Página 125

XSCF> showhardconf SPARC Enterprise xxxx; + Serial:PP20605005; Operator_Panel_Switch:Locked; + Power_Supply_System:Single; SCF-ID:XSCF#0;

Página 126 - Log Archiving

Chapter 4 Operation of the Server 4-34. Use the showstatus (8) command to display information on degraded components in the system. XSCF> showst

Página 127 - Command operation

4-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084.1.2 Display Server Configuration/Status Information Command operation● Use the

Página 128

Chapter 4 Operation of the Server 4-5The displayed information on each I/O boat includes the unit number, serial number, and link information.The d

Página 129 - 2.2.9 SNMP Administration

4-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084.2 Display Domain InformationThis section describes methods for checking the con

Página 130 - SNMP Administration

Chapter 4 Operation of the Server 4-72. Use the showdomainstatus (8) command to check the domain status.XSCF> showdomainstatus -aDID Dom

Página 131

4-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084.3 Adding or Removing DomainsThe system can adopt a domain configuration by comb

Página 132

Chapter 4 Operation of the Server 4-9 sendbreak setpowerupdelay showpowerupdelay setshutdowndelay showshutdowndelay setdualpowerfeed showdua

Página 133 - 4. Confirm the SNMP settings

4-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the poweron (8) command to turn on power to all domains. XSCF> poweron

Página 134 - Setting SNMPv3 Trap

Chapter 4 Operation of the Server 4-112. Use the poweroff (8) command to turn off power to all domains. XSCF> poweroff -aDomainIDs to power off:

Página 135

xx SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008AudienceThis manual is intended for users, specifically SPARC Enterprise system mana

Página 136

4-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the poweron (8) command to turn on power to the specified domain.<Exam

Página 137

Chapter 4 Operation of the Server 4-132. Use the poweroff (8) command to turn off power to the specified domain.<Example 1> Turn off power t

Página 138

4-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Also, even if a system abnormality (like a fan or temperature abnormality) is de

Página 139

Chapter 4 Operation of the Server 4-154.4.6 Domain Reset Command operation1. Use the showdomainstatus (8) command to check the power status of the

Página 140 - 2.2.10 Mail Administration

4-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20083. Use the showdomainstatus (8) command to check the power status of the domain

Página 141 - SMTP Server

Chapter 4 Operation of the Server 4-173. Confirm ok prompt on the specified domain console.Note – To send the break signal to the domain, the domai

Página 142

4-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084.4.9 Warm-Up Time AdministrationThe warm-up time is intended to prevent the PSU

Página 143

Chapter 4 Operation of the Server 4-194.4.10 Shutdown Wait Time AdministrationThe shutdown wait time administration is a setting to delay the shutd

Página 144

4-20 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the setdualpowerfeed (8) command to enable or disable the dual power feed

Página 145 - TABLE 2-23

Chapter 4 Operation of the Server 4-214.5 Identifying the Location of the SystemWhen more than one same type of system is installed in the same are

Página 146

Preface xxi Chapter 6This chapter describes the XSCF mail function. Chapter 7This chapter explains the XSCF SNMP agent function. Chapter 8This chap

Página 147 - DCL Information

<Example 1> The CPU and memory on the motherboard unit (MBU) are degraded due to failure.XSCF> showstatus MBU_B Status:Normal;* ME

Página 148 - XSB Status Information

Chapter 4 Operation of the Server 4-234.6.2 Clearing the Fault/Degradation InformationThe information on a faulty or degraded component is cleared

Página 149 - Parameter Explanation

4-24 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Processing Continued at FailoverIn case the failover was generated while the fol

Página 150 - Domain Component Hardware

Chapter 4 Operation of the Server 4-25TABLE 4-1 lists terms used in External I/O Expansion Unit administration.TABLE 4-1 External I/O Expansion Un

Página 151 - and FIGURE 2-5 are examples

TABLE 4-2 External I/O Expansion Unit Administration Item Description Shell Command RemarksDisplay list Displays a list of External I/O Expansion Uni

Página 152

Chapter 4 Operation of the Server 4-27Note – (2) A locator LED that indicates a location. The names of locator LEDs depend on the corresponding com

Página 153

4-28 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Displaying and Setting the Locator LED State of Each Specified Component in an E

Página 154 - When PSB#n is Uni-XSB type

5-1CHAPTER5Overview of the XSCF ShellThis chapter describes how to use the XSCF Shell. The chapter also describes how to use commands and log in with

Página 155 - When PSB#n is Quad-XSB type

5-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 auditop: The user can refer to the audit method of the XSCF and the audit recor

Página 156 - Domain Configuration

Chapter 5 Overview of the XSCF Shell 5-3setdate Sets the XSCF time.showdate Displays the XSCF time. setntp Configures the NTP server. showntp Displ

Página 157

xxii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008SPARC Enterprise Mx000 Servers DocumentationThe manuals listed below are provided

Página 158 - Displaying the XSB Status

5-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008setarchiving Configures the log archiving function of XSCF.showarchiving Displays

Página 159

Chapter 5 Overview of the XSCF Shell 5-5setdomainmode Sets a hardware initial diagnostic level (No, standard, maximum).Enables or disables break si

Página 160

5-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008showpowerupdelay Displays the warm-up time and the air-conditioning wait time set

Página 161

Chapter 5 Overview of the XSCF Shell 5-75.2 Login to XSCF User AccountsThis section describes how to log in to XSCF. The user can log in to XSCF fr

Página 162 - TABLE 2-23.)

login: jsmithPassword: xxxxxxxxXSCF>5-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20085.2.3 Operation for Connecting Via the XSC

Página 163 - TABLE 2-22.)

Chapter 5 Overview of the XSCF Shell 5-9When the SSH connection is done using a user key, install the user public key in XSCF in advance. See Chapt

Página 164

5-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20085.3 View Server Status and Control CommandsThis section describes the typical XS

Página 165

Chapter 5 Overview of the XSCF Shell 5-11fmadm / fmdump / fmstatThe server has an architecture that performs fault management (FMA) for CPUs, memor

Página 166

5-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20085.4 Server Configuration Information CommandsThis section describes the typical

Página 167

Chapter 5 Overview of the XSCF Shell 5-13showstatusThe system administrator can use the showstatus (8) command to list degraded components. 5.5 Dom

Página 168

Preface xxiii1. Manuals on the WebThe latest versions of all the SPARC Enterprise Series manuals are available at the following websites.Global Siteht

Página 169 - System Board Configuration

5-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008showdcl / setdclThe showdcl (8) command displays the domain configuration inform

Página 170 - Dividing a PSB Into XSBs

Chapter 5 Overview of the XSCF Shell 5-155.6 View and Archive the XSCF LogsThis section describes the XSCF commands that fetch and display server o

Página 171

5-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008showuser / adduser / deleteuser / enableuser / disableuserThe showuser (8) comma

Página 172

Chapter 5 Overview of the XSCF Shell 5-17exitThe exit (8) command ends the XSCF Shell.versionThe version (8) command displays the comprehensive fir

Página 173

5-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 174 - Domain Mode Configuration

6-1CHAPTER6XSCF Mail FunctionThis chapter describes the XSCF mail function.6.1 Overview of XSCF Mail FunctionThe mail report function, used by XSCF fi

Página 175

6-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 6-1 outlines the XSCF mail function.FIGURE 6-1 XSCF Mail FunctionSystemXS

Página 176 - FIGURE 2-8

Chapter 6 XSCF Mail Function 6-3Parts Fault NotificationXSCF monitors components (such as CPU modules, FAN units, CMU) in the server. XSCF can noti

Página 177

6-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Select POP authentication or SMTP authentication—(See setsmtp (8))Reply address (

Página 178

Chapter 6 XSCF Mail Function 6-56.3 Contents of Parts Fault NotificationThis section explains the contents of the email messages sent for parts fau

Página 179

xxiv SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084. Manual (man page) provided in the systemXSCF man pageNote – The man page can be

Página 180

6-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 MSG-ID: Message ID. Use the message ID for accessing the specified URL to acqui

Página 181

7-1CHAPTER7XSCF SNMP Agent FunctionThis chapter explains the XSCF SNMP agent function.7.1 Overview of the XSCF SNMP AgentXSCF supports the simple netw

Página 182

7-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 7-1 Example of a Network Management EnvironmentSNMP SNMP is a protocol fo

Página 183 - Setting Altitude

Chapter 7 XSCF SNMP Agent Function 7-37.2 MIB Definition FileThe SNMP agent responds with management information from the Management Information Ba

Página 184

7-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008The following shows data as an example of MIB management information.scfMachineTy

Página 185

Chapter 7 XSCF SNMP Agent Function 7-57.3 About TRAPWhen an event occurs, the SNMP agent function notifies the SNMP manager of the event. This func

Página 186

TRAP agent:10.123.223.18 community:- generic:6enterprise:enterprises.42.2.195.1.7 specific:1 timestamp:754201501varbind:(enterprises.42.2.195.1.1.1.2.

Página 187

Chapter 7 XSCF SNMP Agent Function 7-7FIGURE 7-2 is a conceptual diagram of issuance of a TRAP. FIGURE 7-2 TRAP IssuanceTrap issuedSystemXSCFEvent

Página 188

7-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20087.4 Setting Up the XSCF SNMP Agent FunctionThis section explains how to set up th

Página 189

Chapter 7 XSCF SNMP Agent Function 7-9 Community name Port number of the trap destination Host name of the trap destination Step 3: Enable the

Página 190

Preface xxv7. Provided In firmware program CD (For maintenance service <for FEs>)i. Firmware program file (XSCF Control Package (XCP) file)ii. X

Página 191

7-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Performing User Management (USM Management) and Management of the Access Control

Página 192

8-1CHAPTER8Upgrade of XSCF Firmware and MaintenanceThis chapter explains how to update the firmware and how to collect log data. 8.1 Update the XSCF F

Página 193 - Ethernet

8-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – XCP: Abbreviation for XSCF Control Package. XCP is a package that has the

Página 194

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-32. Update (includes application of the XSCF firmware) Note – The OpenBoot PROM firmware is ap

Página 195 - Function Connection Direction

8-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Firmware Update EnvironmentThe following environment is required for the firmware

Página 196

XSCF> version -c xcpXSCF#0 (Active)XCP0 (Current) : 1020XCP1 (Reserve) : 1020XSCF#1 (Standby)XCP0 (Current) : 1020XCP1 (Reserve) : 1020Chapter 8

Página 197

8-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. UpdateWriting the XSCF and OpenBoot PROM firmware programs that were imported

Página 198

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-78.1.7 Firmware Update Types and TimingThe firmware update includes two types: operator's

Página 199

8-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – (1) Corresponds to an MBU in a midrange system. (The same is true for the

Página 200 - Domain Console

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-9Making Versions Agree With Each OtherXSCF automatically sets firmware versions to match each

Página 201 - 3.2 Types of XSCF Connections

xxvi SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008ModelsThe model names used in this manual are as follows.Server class Model nameMi

Página 202 - DomainID n

TABLE 8-2 Firmware Update Tasks Firmware Update Task Item Outline Task timeUpdating XCP From the NetworkObtain the XCP files from the appropriate web

Página 203

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-11Updating XCP From the Network File preparation:1. Download the XCP files from a public site

Página 204

8-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008b. Use the getflashimage (8) command to specify the firmware program (tar.gz) fi

Página 205

XSCF> version -c xcp -vXSCF#0 (Active)XCP0 (Current) : 1010OpenBoot PROM : 01.01.0001XSCF : 01.01.0001XCP1 (Reserve)

Página 206

8-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – The display might be different according to XCP version and system config

Página 207

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-154. Import XCP.a. Display the XCP import window.b. Following instructions in the window, s

Página 208

8-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Updating XCP From External Media1. Insert the external media with the XCP file i

Página 209 - Operation of the Server

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-171. After doing an XSCF Unit replacement task by using the maintenance guidance for FEs, the

Página 210

8-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081. Repeat Step 1 and Step 2 of the Command operation. Then login to the XSCF on

Página 211

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-19Q: In cases with redundant XSCF Units, why are the XSCF Units on the active and standby side

Página 212

Preface xxviiPrompt NotationsThe prompt notations used in this manual are as follows.Shell Prompt NotationsXSCF XSCF>C shell machine-name%C shell s

Página 213

TABLE 8-3 Logs Containing Fault Information Type DescriptionSize (Entry Size)Output/Display Destination (Standard Storage Period) Archiving Refere

Página 214 - 4.2.1 Domain Information

TABLE 8-4 Other Logs Type DescriptionSize(Entry)Standard Storage Period Archiving Reference MethodPower log Log for recording power events of the

Página 215

8-22 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20088.2.2 Method of Collecting the Log InformationThe field engineers and authorized

Página 216

Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-234. Set the encryption password used for encrypting the output log file.5. Execute the data t

Página 217 - 4.4.1 System Power On

8-24 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – For detail of snapshot (8) command, including how to enable encryption, s

Página 218 - 4.4.2 System Power Off

9-1CHAPTER9How to Use the XSCF Web This chapter describes how to use the XSCF Web. 9.1 Overview of the XSCF WebThe XSCF Web uses https and the SSL/TLS

Página 219 - 4.4.3 Domain Power On

TABLE 9-1 XSCF Web Pages Basic Page DescriptionLogin page XSCF Web console login page. Log in with an XSCF user account from the login page.Menu fra

Página 220 - 4.4.4 Domain Power Off

Chapter 9 How to Use the XSCF Web 9-3FIGURE 9-1 shows an example of the Login page.FIGURE 9-1 Example of the Login PageXSCF Web ConsoleXSCF Web Co

Página 221

9-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 9-2 shows an example of the Tree frame.FIGURE 9-2 Example of the Tree Fra

Página 222

Chapter 9 How to Use the XSCF Web 9-5FIGURE 9-3 shows an example of the Tree frame and main page.FIGURE 9-3 Example of the Tree Frame and Main Pag

Página 223

SPARC® Enterprise M4000/M5000/M8000/M9000 Servers XSCF User’s GuideManual Code C120-E332-06ENPart No. 819-7889-13April 2008, Revision A

Página 224

xxviii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Conventions for Important MessagesThis manual uses the following conventions to

Página 225

9-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20089.2.1 PrerequisitesSome settings are disabled in the initial settings of the XSCF

Página 226 - XSCF> showpowerupdelay

Chapter 9 How to Use the XSCF Web 9-79.2.4 Specifying the URLWhen specifying the URL, specify the IP address configured with XSCF or the XSCF host

Página 227

9-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008The authentication timeout setting can be changed. The authentication timeout is

Página 228

Chapter 9 How to Use the XSCF Web 9-99.4 XSCF Web PagesThis section describes the configuration of pages available with the XSCF Web console.Menu a

Página 229

(Continued) + Utility - Firmware Update - Switch Over - Reboot XSCF + Logs - Error Log - Power Log - Event Log - Console Log

Página 230

Chapter 9 How to Use the XSCF Web 9-11Displaying System StatusTABLE 9-3 lists the functions for displaying the status of the entire system. Select

Página 231 - 4.8 Switching the XSCF Unit

TABLE 9-5 Device Status Display Function RemarksCPU status display Displays the CPU status corresponding to a specified XSB number or Domain ID.This

Página 232 - ■ DR function

Chapter 9 How to Use the XSCF Web 9-13System and Domain OperationTABLE 9-6 lists the function used for the system as a whole and individual domains

Página 233 - Administration Terms

9-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 9-8 lists the functions used for System board configuration. Select [Opera

Página 234

Chapter 9 How to Use the XSCF Web 9-15TABLE 9-9 lists the functions for the domain configuration. Select [Operation]-[Domain Configuration]-[Domain

Página 235

Preface xxixFujitsu Welcomes Your CommentsWe would appreciate your comments and suggestions to improve this document. You can submit your comments by

Página 236

9-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Setting SystemTABLE 9-10 lists the functions for Network configuration of XSCF.

Página 237 - Overview of the XSCF Shell

Chapter 9 How to Use the XSCF Web 9-17TABLE 9-11 lists the functions for setting the XSCF time. Select [Settings]-[Time] in the Menu tree.TABLE 9-1

Página 238 - XSCF Commands

9-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 9-13 lists the functions for configuring LDAP. Select [Settings]-[LDAP] in

Página 239 - XSCF Commands (Continued)

Chapter 9 How to Use the XSCF Web 9-19TABLE 9-15 lists the functions for configuring XSCF audit. Select [Settings]-[Audit]in the Menu tree.TABLE 9-

Página 240

TABLE 9-16 Mail Configuration (SMTP) Function RemarksSMTP server display and configuration Displays SMTP server setting information. Sets the host na

Página 241

Chapter 9 How to Use the XSCF Web 9-21TABLE 9-18 lists the functions for configuring SNMP for XSCF. This page provides the SNMPv1v2c and SNMPv3 set

Página 242

9-22 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 9-20 lists the functions for configuring Log archiving for XSCF. Select [S

Página 243 - Serial Port

Chapter 9 How to Use the XSCF Web 9-23TABLE 9-21 lists the functions for configuring COD. Select [Setting]-[Capacity on Demand] in the Menu tree.TA

Página 244

9-24 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008UtilityThe Pages of Utility include remote maintenance service, firmware update,

Página 245 - (Telnet)

Chapter 9 How to Use the XSCF Web 9-25LogsTABLE 9-24 lists the functions for referring and saving each log. Select [Logs] in the Menu Tree, and sel

Página 246 - Commands

xxx SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Reader's Comment Form

Página 247

9-26 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Component InformationTo refer to the information and status of physical componen

Página 248

A-1APPENDIXAWarning and Information MessagesThis appendix explains the XSCF fault and informational messages output during the operation with the cons

Página 249

A-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008This message is output in case of panic. The panic message is output to the domain

Página 250

Appendix A Warning and Information Messages A-3In addition to the messages above, there is a notification message displayed on the domain console w

Página 251

A-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Fault information in the FMA message is stored in the log. Therefore, the log fi

Página 252 - ■ version

Appendix A Warning and Information Messages A-5Recognizing Status Notification or Fault Information in an SNMP Trap Message1. The user recognizes s

Página 253 - Message Meaning

A-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 254

B-1APPENDIXBXSCF Log InformationThis appendix explains the following XSCF log information that can be referenced using the XSCF Shell showlogs (8) com

Página 255 - XSCF Mail Function

B-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008The showlogs (8) error option displays fault information in a format specific to th

Página 256 - XSCF Email Notification Path

Appendix B XSCF Log Information B-3 Replacement component (FRU) that is probably faulty. A comma (,) separates two suspect components displayed. F

Página 257 - Parts Fault Notification

FOLD AND TAPEFOLD AND TAPEBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO 741 SUNNYVALE CANO POSTAGE NECESSARYIF MAILEDIN THEUNITED STATESPOSTAGE WILL

Página 258 - ■ Step 4: Send test mail

B-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the message ID for accessing the specified URL to acquire detailed informati

Página 259 - FIGURE 6-3 (No.1 to 3 in the

Appendix B XSCF Log Information B-53. After confirming the problem, repair the fault according to the recommended processing.For details of the fmd

Página 260 - 6.4 Test Mail

Event MeaningSCF Reset: The XSCF was reset.Domain Power ON: The domain power supply was turned on.Domain Power OFF: The domain power supply was turne

Página 261 - XSCF SNMP Agent Function

Switch status MeaningLocked: The mode switch is locked.Service: The mode switch is in service.Appendix B XSCF Log Information B-7B.3 Event LogWhen

Página 262

B-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008B.4 Using the showlogs Command to Display Other LogsThis section explains how to re

Página 263 - 7.2 MIB Definition File

Appendix B XSCF Log Information B-9 Power supply status (ON or OFF) of the server (Power).B.4.3 Console LogUsing the showlogs (8) Command to Refer

Página 264

B-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008B.4.5 IPL LogUsing the showlogs (8) Command to Reference IPL LogsAfter the domain

Página 265 - 7.3 About TRAP

<Example> Display all audit records.XSCF> viewaudit file,1,2006-04-26 21:37:25.626 +00:00,20060426213725.0000000000.SCF-4-0header,20,1,audit

Página 266

B-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 Text TokenLabel, text stringNote – Some fields might not be output according to

Página 267 - TRAP Issuance

C-1APPENDIXCXSCF MIBThis appendix explains the XSCF Management Information Base (MIB), which is supported by the XSCF SNMP agent function.C.1 MIB Obje

Página 268 - Function

xxxii SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 269 - ■ Step 3:

C-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008udp OBJECT IDENTIFIER ::= { mib-2 7 }snmp OBJECT IDENTIFIER ::= { mib-2 11 }enterpr

Página 270 - Management)

Appendix C XSCF MIB C-3C.2 Standard MIBThe standard MIB supported by the XSCF conforms to the following RFC (Note). For the standard MIB definition

Página 271 - Maintenance

C-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081. scfInfo groupThis group provides general information pertaining to the XSCF.2. s

Página 272

Appendix C XSCF MIB C-5Obtaining the Latest Extension MIBFor details on obtaining the XSCF extension MIB definition file and the Fault Management M

Página 273 - User Privileges

C-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Página 274 - Firmware Update Environment

D-1APPENDIXDTroubleshootingThis chapter describes problems that can occur during use of the XSCF console or during the operation of the system and pro

Página 275 - ■ z = Micro release number

D-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Could Not Connect to XSCF Through the Serial Port Check the connection between the

Página 276

Appendix D Troubleshooting D-3Do Not Know the IP Address of XSCF Use the shownetwork (8) command to check the current network configuration. If it

Página 277

D-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008A Mail Report Was Not Received From XSCF XSCF does not necessarily report all even

Página 278 - Supported Hardware

Appendix D Troubleshooting D-5Web Pages of the XSCF Web Function are not Displayed Correctly Some versions of web browsers do not display the wind

Página 279

1-1CHAPTER1XSCF OverviewThis chapter provides an overview of the system monitoring and control facility (eXtended System Control Facility, or XSCF).1.

Página 280 - Firmware Update Tasks

D-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20083. After doing Step 2, if the reset operation or the "sync" command fails

Página 281 - Updating XCP From the Network

Appendix D Troubleshooting D-7The following example shows an unsuccessful log out:XSCF> exitNot supported in this system.Note – The above exampl

Página 282

D-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008b. Establish a connection through the XSCF-LAN port, and use the XSCF Shell to che

Página 283

E-1APPENDIXESoftware License ConditionsSome of the software functions explained in this manual are licensed under public licenses (GNU Public License

Página 284 - XSCF> showlogs monitor

E-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008GNU GENERAL PUBLIC LICENSEVersion 2, June 1991 Copyright (C) 1989, 1991 Free Sof

Página 285

Appendix E Software License Conditions E-3 6. Each time you redistribute the Program (or any work based on the Program), the recipient automatica

Página 286 - Has Been Added or Replaced

E-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 When we speak of free software, we are referring to freedom of use, not price.

Página 287 - ■ Web browser operation

Appendix E Software License Conditions E-5 3. You may opt to apply the terms of the ordinary GNU General Public License instead of this License t

Página 288

E-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008of software distributed through that system in reliance on consistent applicatio

Página 289 - 8.2 Collecting XSCF Logs

Appendix E Software License Conditions E-7 * notice, this list of conditions and the following disclaimer. * 2. Redistributions in binary form

Página 290 - Other Logs

1-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – (2) Only the system model with a special interface can power on and off th

Página 291

E-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Copyright (c) 1998, 1999, 2000 Thai Open Source Software Center Ltd

Página 292 - Front Panel of the XSCF Unit

Appendix E Software License Conditions E-9 * * 1. Redistributions of source code must retain the above copyright notice, this * list of condition

Página 293 - XSCF> snapshot -d usb0

E-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 200812) Miscellaneous. This License represents the complete agreement concerning th

Página 294 - File format : zip

Appendix E Software License Conditions E-11 6. Trademarks. This License does not grant permission to use the trade names, trademarks, service ma

Página 295 - How to Use the XSCF Web

E-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008/* * Copyright (c) 1991 Bell Communications Research, Inc. (Bellcore) * * Permi

Página 296 - XSCF Web Pages

Appendix E Software License Conditions E-132. Redistributions in binary form must reproduce all prior and current copyright notices, this list of

Página 297 - XSCF Web Console

E-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008* Redistributions in binary form must reproduce the above copyright notice, th

Página 298 - Example of the Tree Frame

Appendix E Software License Conditions E-15 [However, none of that term is relevant at this point in time. All of these restrictively licenced

Página 299 - 9.2 Start the XSCF Web

E-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 * * 2. Redistributions in binary form must reproduce the above copyright * n

Página 300 - 9.2.2 Supported Browsers

Appendix E Software License Conditions E-17----/*- * Copyright (c) 1990 The Regents of the University of California. * All rights reserved. * * Re

Página 301 - 9.3.1 Logging in to XSCF

Chapter 1 XSCF Overview 1-3Note – (3) The RCI is the power and system control interface that interconnects I/O units with the server, including pro

Página 302 - 9.3.3 Logging Out From XSCF

E-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 * INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL * DAMAGES (INCLUD

Página 303 - 9.4 XSCF Web Pages

Index-1IndexAAdding and deleting COD license keys, 2-133Adding or deleting a user account and specifying a password, 2-32Administrationaltitude, 2-

Página 304 - Chapter 2 and Chapter 5

Index-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008CPU operational modes, 2-120cpumode, 2-120cpumode,auto, 2-120cpumode,compati

Página 305 - Displaying System Status

Index-3MMail administration, 2-84Mail report functionenabling or disabling, 2-86Making XSCF DNS settings, 2-27Management informationUSM, 2-81VA CM

Página 306 - Device Status Display

Index-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008SSH/telnet Administration, 2-48Stratum Valuechanging in XSCF, 2-46System Boar

Página 309

1-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008RCI Port (Note)When connecting a peripheral device (devices with an RCI connector

Página 310 - Setting System

Chapter 1 XSCF Overview 1-5ACT LEDLocated on each of the LAN ports, the ACT LED is a LAN LED that lights up in green. When the communication state

Página 311 - SSH/telnet Settings

PleaseRecycleCopyright 2007-2008 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japan. All rights reser

Página 312 - Menu tree

1-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008XSCF Unit Front Panels on the High-End SystemsFIGURE 1-2 includes an outline draw

Página 313 - Audit Configuration

Chapter 1 XSCF Overview 1-7The Link Speed LED, ACT LED, XSCF-LAN port, USB port, serial port, RCI port, READY LED, and CHECK LED shown in have the

Página 314 - Mail Configuration (SMTP)

1-8 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008XSCF Unit DiagnosisWhen the input power is turned on or the XSCF is rebooted, XSC

Página 315 - SNMP Configuration

Chapter 1 XSCF Overview 1-9The user can power on and off the server by using XSCF as follows: Power on/off the server or a domainThe user can turn

Página 316 - Log Archiving Configuration

1-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Component Configuration Recognition and Temperature/Voltage MonitoringXSCF monit

Página 317 - Demand] in the Menu tree

Chapter 1 XSCF Overview 1-11Functions for Monitoring and Notification During OperationXSCF constantly monitors the system operating status, FAN sta

Página 318 - Firmware Updating

1-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081.3 Types of Connection to XSCFThis section outlines types of connection to the

Página 319 - Log Collection

Chapter 1 XSCF Overview 1-13 Serial port connection XSCF-LAN Ethernet connectionSerial Port ConnectionThe serial port enables workstations, PCs,

Página 320 - 9.5 XSCF Web Error Messages

TABLE 1-1 XSCF-LAN Operation Examples 1 LAN Name OperationXSCF-LAN0 port • For system administrator operationThe system administrator can control th

Página 321 - A.1 Message Types

Chapter 1 XSCF Overview 1-15XSCF-LAN RedundancyIn the midrange systems, the XSCF-LAN paths can be made redundant (duplicated). If a LAN failure occ

Página 322 - ■ Other notice message

Copyright 2007-2008 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japon. Tous droits réservés.Entrée e

Página 323 - A.2 Messages in Each Function

1-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008FIGURE 1-5 Two XSCF-LANs and Two XSCF Units ConfigurationActiveXSCFStandbyXSCFS

Página 324

Chapter 1 XSCF Overview 1-171.3.2 NTP Configuration and Time SynchronizationThe system uses the XSCF Unit clock for the system standard time. The d

Página 325

1-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081.3.3 About the CD-RW/DVD-RW Drive Unit and Tape Drive UnitA basic cabinet and a

Página 326

Chapter 1 XSCF Overview 1-19Sends email reports of the system status.Caution – IMPORTANT – To use the function as explained above, you must create

Página 327 - XSCF Log Information

TABLE 1-5 XSCF Functions and Connection Ports Functions Contents Serial portXSCF LAN EthernetXSCF Shell • Monitors the serverThe status of the system

Página 328

Chapter 1 XSCF Overview 1-21For example, to set up a domain administrator, the user privilege for the domain is specified. Moreover, you can provid

Página 329

1-22 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – The Audit function monitors user operations and keeps a detailed access r

Página 330

2-1CHAPTER2Setting Up XSCFThis chapter explains how to set up XSCF.2.1 XSCF Setup SummaryEach XSCF function must be configured before it can be used.

Página 331 - B.2 Power Log

2-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008 COD Administration (optional) Note – This document does not provide details on

Página 332

Chapter 2 Setting Up XSCF 2-3 Default user account: default The user privileges are useradm, platadm. Default password:The default password is no

Página 334 - Display Other Logs

2-4 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Set the password policy.• Display and set a password policy. showpasswordpolic

Página 335 - B.4.4 Panic Log

Chapter 2 Setting Up XSCF 2-54. Set the time.• Set and display the time zone. • Set and display the XSCF time. showtimezone(8)settimezone(8)showdat

Página 336 - B.5 Audit Log

XSCF> showsshSSH status: enabledRSA key:ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEArmf46B4xSvunUNZPWOi4mRbqO9hsunxHitwR/0P6NTQbNK8BqCpCsyzK6nfjrARztO1rgXI

Página 337

Chapter 2 Setting Up XSCF 2-78. Configure the network.• Display and set the DSCP.• Display XSCF network settings (enable/disable, IP address, netma

Página 338

Enter passphrase for key ’/home/nana/.ssh/id_rsa’ :xxxxxxxxWarning: No xauth data; using fake authentication data for X11 forwarding.Last login: Fri S

Página 339 - XSCF MIB

Chapter 2 Setting Up XSCF 2-912. Configure the log archiving settings. • Display log archiving settings and configure log archiving. showarchiving(

Página 340

2-10 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 200817. Configure the domain settings.• Display domain information and specify the d

Página 341 - C.3 Extended MIB

Chapter 2 Setting Up XSCF 2-1120. Configure the Altitude Administration settings.• Make the Altitude Administration. showaltitude(8), setaltitude(

Página 342

2-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20081. Connect to and log in to XSCF (serial). (Same as Step 1 in Section 2.1.1, “Se

Página 343 - C.4 Trap

<Web browser screen image>URL https://192.168.111.111/ (The IP address of XSCF is input by number)Alternatively:https://XSCF-host-name/ (Not the

Página 344

vContentsContents vFigures xiiiTables xvPreface xixAudience xxGlossary xxStructure and Contents of this Manual xxSPARC Enterprise Mx000 Servers

Página 345 - Troubleshooting

2-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082.2 Specifying the XSCF SettingsThis section describes the XSCF settings in deta

Página 346

Chapter 2 Setting Up XSCF 2-152.2.1 Network ConfigurationNetwork Configuration is used to specify items relating to network interfaces, routing, an

Página 347 - Could Not Add an XSCF User

2-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 2-2 Network Configuration Item Description Shell Command RemarksDisplay n

Página 348

Chapter 2 Setting Up XSCF 2-17Note – To complete the network settings, the XSCF reset is required. Reset the XSCF by using the rebootxscf (8) comma

Página 349 - Other Problems

2-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Note – In systems with two XSCF Units (the high-end systems), the two XSCF Units

Página 350

Chapter 2 Setting Up XSCF 2-19FIGURE 2-1 Network Interface Required for XSCF Network Configuration (In the High-End Systems)7,8; Addresses of Int

Página 351 - Is Being Used

Number Description Number Description1 XSCF-LAN#0 address (XSCFU#0 side)7 ISN address (XSCFU#0 side)2 XSCF-LAN#0 address (XSCFU#1 side)8 ISN address

Página 352

Chapter 2 Setting Up XSCF 2-21To make the IP address redundant, specify the same subnet address to the LAN port of XSCFU#0 side and to the LAN port

Página 353 - Software License Conditions

2-22 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008(See applynetwork (8), rebootxscf (8).) Note – While any of the setting commands

Página 354

Chapter 2 Setting Up XSCF 2-232. Use the showdscp (8) command to display DSCP information.<Example> Display DSCP information.XSCF> showdsc

Página 355

vi SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Fujitsu Welcomes Your Comments xxixReader's Comment Form xxx1. XSCF Overview

Página 356

2-24 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20084. Use the setdscp (8) command (see Note) to specify network interface informati

Página 357

Chapter 2 Setting Up XSCF 2-25Note – If you set a netmask using the -m option, this netmask value shows the mask value in the XSCF network. A netma

Página 358

2-26 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Configuring XSCF Routing<Example>XSCF Unit 0 XSCF Unit 1xscf#0

Página 359

Chapter 2 Setting Up XSCF 2-272. Use the setroute (8) command to specify the routing environment for a network interface.<Example 1> Add rout

Página 360

2-28 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Applying the XSCF Network Settings Command operation1. After performing the set

Página 361

Chapter 2 Setting Up XSCF 2-295. Use the nslookup (8) command to check the host name information.<Example> Specify the host name information

Página 362

2-30 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008TABLE 2-4 User Account Administration Item Description Shell Command RemarksDis

Página 363

Chapter 2 Setting Up XSCF 2-31Note – If the password policy is set, then the password policy is applied to the users added after that.Note – When y

Página 364

2-32 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Adding or Deleting a User Account and Specifying a Password Command operation1.

Página 365

Chapter 2 Setting Up XSCF 2-333. Use the password (8) command to specify a password.<Example 1> Specify a password.XSCF> password jsmithCh

Página 366

Contents vii2.2.12 System Board Configuration 2–1132.2.13 Domain Mode Configuration 2–1162.2.14 Locale Administration 2–1262.2.15 Altitude Administ

Página 367

XSCF> showuser -pUser Name: jsmithPrivileges: useradm auditadm2-34 SPARC Enterprise Mx000 Servers XSCF User’s Gu

Página 368

Chapter 2 Setting Up XSCF 2-352. Use the setpasswordpolicy (8) command to specify a password policy.<Example> Specify 3 for the retry count,

Página 369

TABLE 2-5 LDAP Administration Terms Term DescriptionLDAP Abbreviation for Lightweight Directory Access Protocol.LDAP is a protocol used to access dir

Página 370

Chapter 2 Setting Up XSCF 2-37Note – PEM: Abbreviation for Privacy Enhanced Mail. Mail to be sent is encrypted for increased privacy.Enabling or Di

Página 371

2-38 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 20082. Use the setlookup (8) command to enable or disable the LDAP server.<Exampl

Página 372

Chapter 2 Setting Up XSCF 2-393. Use the showldap (8) command to confirm the setting.XSCF> showldapBind Name: cn=Directory Manager

Página 373

2-40 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Testing a Connection to an LDAP Server Command operation1. Use the setldap (8)

Página 374

Chapter 2 Setting Up XSCF 2-41 A Solaris OS domain can be set up as an NTP client with the XSCF Unit being the NTP server. In this case, the XSCF

Página 375

2-42 SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008Specifying a Time Zone Command operation1. Use the showtimezone (8) command to

Página 376

Chapter 2 Setting Up XSCF 2-432. Use the settimezone (8) command to set the system time. The platadm privilege is required.<Example 1> Displa