TABLE 1-1 XSCF-LAN Operation Examples 1
LAN Name Operation
XSCF-LAN0 port For system administrator operation
The system administrator can control the server, control
domains, and display the console using the XSCF Shell.
XSCF-LAN1 port For field engineer operation
Field engineers can configure the server and perform
maintenance tasks using the XSCF Shell.
For remote maintenance service operation
TABLE 1-2 XSCF-LAN Operation Examples 2
LAN Name Operation
XSCF-LAN0 port For system administrator operation
For remote maintenance service operation
XSCF-LAN1 port Not used
1-14 SPARC Enterprise Mx000 Servers XSCF User’s Guide April 2008
Note – The serial port is used by maintenance engineers.
TABLE 1-3 XSCF-LAN Operation Examples 3
LAN Name Operation
XSCF-LAN0 port For system administrator operation
For maintenance operation
For remote maintenance service operation
XSCF-LAN1 port Same as above
Caution – IMPORTANT - The IP address of XSCF-LAN#0 and the IP address of
XSCF-LAN#1 must be specified in different subnet addresses.
Note – The two XSCF-LAN ports are used for the same purpose (alternate path
configuration). For details on these connections, see Chapter 3.