Fujitsu SPARC ENTERPRISE T5120 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Computadores Fujitsu SPARC ENTERPRISE T5120. FUJITSU SPARC ENTERPRISE T5120 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Product Notes

SPARC® EnterpriseT5120 and T5220 ServersProduct NotesOrder No. U41752-J-Z816-1-76Part No. 875-4197-10October 2007, Revision

Página 2

x SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Documentation Errata 48

Página 3

1Important Information About the SPARC Enterprise T5120 and T5220 ServersThese product notes contain important and late-breaking information about the

Página 4

2 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Technical SupportIf you have technical questions or issues that are not address

Página 5 - Contents

Important Information About the SPARC Enterprise T5120 and T5220 Servers 3 System firmware 7.0.3, which includes Integrated Lights Out Manager (ILOM)

Página 6

4 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007The following table lists the software preinstalled on your server.The followin

Página 7 - Contents vii

Important Information About the SPARC Enterprise T5120 and T5220 Servers 5http://www.sun.com/servers/coolthreads/overview/cooltools.jspNot all of the

Página 8

6 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Solaris Live UpgradeSolaris Live Upgrade technology significantly reduces servi

Página 9 - Contents ix

Important Information About the SPARC Enterprise T5120 and T5220 Servers 7The following patches are required for your server:Note – Before contacting

Página 10 - Documentation Errata 48

8 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007For example, if patch 119578-16 or later is installed, your system has the requ

Página 11

Important Information About the SPARC Enterprise T5120 and T5220 Servers 9 Solaris Volume Manager (attached to Solaris OS) LDOM Manager The SPARC Ent

Página 12 - System Firmware

PleaseRecycleCopyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.FUJITSU LIMITED pro

Página 13 - Updating System Firmware

10 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Unexpected LED BehaviorThere is a LED behavior that occurs when you create a v

Página 14 - Technology

Important Information About the SPARC Enterprise T5120 and T5220 Servers 11Workaround: Use the virtual-console as the input device.Inconsistent Consol

Página 15 - Logical Domains

12 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Though no error or fault is reported, it is easy to identify due to the fact t

Página 16 - Mandatory Patch Information

Important Information About the SPARC Enterprise T5120 and T5220 Servers 13Panic in nxge_start When dupb Fails (CR 6567838)If jumbo frames are enabled

Página 17 - To Download Patches

14 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 20071. Jumbo frame is enabled because the following line is present and not commen

Página 18 - Limitations

Important Information About the SPARC Enterprise T5120 and T5220 Servers 15Workaround: If jumbo frame is to be enabled, set the MTU to 8172 by doing t

Página 19 - Hotswapping Fan Modules

16 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Physical-Platform Information Missing From prtpicl and prtdiag (CR 6586624)The

Página 20 - Software Issues

Important Information About the SPARC Enterprise T5120 and T5220 Servers 17Workaround: Reboot the system by dropping to the service processor (SP) and

Página 21 - Console (CR 6581309)

18 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007The following formatting issues could be displayed in the prtdiag -v command o

Página 22

Important Information About the SPARC Enterprise T5120 and T5220 Servers 19In the ILOM CLI, to set the locator LED to on or off:prtdiag -v Voltage Ind

Página 23 - 99.99.9.1 nxge-port1

Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.Entrée et revue tecnical f

Página 24

20 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Firmware and General Software IssuesIPMI Chassis Power Cycle Does Not Always W

Página 25

Important Information About the SPARC Enterprise T5120 and T5220 Servers 21Workaround: Use Auto-Negotiation to set the Link Speed/Duplex. For example,

Página 26 - (CR 6588499)

22 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007The following is an example of dumping the event:These events are harmless and

Página 27 - Driver (CR 6479347)

Important Information About the SPARC Enterprise T5120 and T5220 Servers 23rm-io Followed by Multiple set-vcpu Operations Could Cause HV Abort or ldmd

Página 28

24 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007It is usually not necessary to unload a driver from a running kernel, but in t

Página 29 - When Run Again (CR 6552999)

Important Information About the SPARC Enterprise T5120 and T5220 Servers 25When Either NIU Port in the N2 CPU is Disabled the Corresponding XAUI is Co

Página 30 - No keyboard support found

26 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Workaround: Add the following setting to the /etc/system file.mpt Handles SMAR

Página 31

Important Information About the SPARC Enterprise T5120 and T5220 Servers 27ldc_skt and ds Might Not Handle LDC Resets Properly (CR 6583567)Very rarely

Página 32

28 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007ID 216524 daemon.error Registration With DMI Failederr = 831 (CR 6237994)Regis

Página 33

Important Information About the SPARC Enterprise T5120 and T5220 Servers 29After the control domain recovers, there is a diagnosis performed. Messages

Página 35

30 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Unable to Remove RAID 1 Volume After RAID 1 and RAID 0 Volumes Are Created (CR

Página 36 - 6561389)

Important Information About the SPARC Enterprise T5120 and T5220 Servers 31OpenBoot PROM Banner Shows the Same Memory Number After Disabling a DIMM an

Página 37 - 6583567)

32 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007 When running in a factory-default configuration, variable updates specified

Página 38 - (CR 6594506)

Important Information About the SPARC Enterprise T5120 and T5220 Servers 33A common way to encounter this error is if you left off the = sign when usi

Página 39 - Features

34 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 20071. The system is booted in the factory-default configuration.2. The user chan

Página 40

Important Information About the SPARC Enterprise T5120 and T5220 Servers 35The system will continue to boot, but in a degraded state. During the boot

Página 41 - ■ At the OpenBoot prompt

36 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Use fmdump -eV -u uuid with the UUID from the console message to determine if

Página 42

Important Information About the SPARC Enterprise T5120 and T5220 Servers 37Workaround: If system fails to boot because of this problem, retry it.Proce

Página 43

38 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Missing CPU Cores and Strands Shown in PICL Physical-Platform Tree (CR 6596503

Página 44

Important Information About the SPARC Enterprise T5120 and T5220 Servers 39Where MSGID is one of the PSH Message ID's listed above and displayed

Página 45 - Memory Faults (CR 6592272)

vContentsImportant Information About the SPARC Enterprise T5120 and T5220 Servers1Support for the SPARC Enterprise T5120 and T5220 Servers 1Technical

Página 46 - Later (CR 6553515)

40 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Use setdefaults Command to Clear Last POST Run From showfaults (CR 6573354)Aft

Página 47 - %PC f0238978 %nPC f023897c

Important Information About the SPARC Enterprise T5120 and T5220 Servers 41uadmin 2 0 and reboot Reads Old Bootmode Settings (CR 6585340) You can chan

Página 48 - DIMM (CR 6582853)

42 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007ALOM CMT Compatibility CLI Displays Incorrect Guest Status Sent From OpenBoot

Página 49 - Logging out after 60 seconds

Important Information About the SPARC Enterprise T5120 and T5220 Servers 43The following is sample output of sending a break to the Solaris host from

Página 50

44 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 20073. Enter the break command as follows.Log back into the Solaris host with the

Página 51 - 6585340)

Important Information About the SPARC Enterprise T5120 and T5220 Servers 45Intermittent Issue With netsc commit and showsc Hang (CR 6549028)The netsc_

Página 52 - Work (CR 6577528)

46 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007If you run consolehistory -e with a value greater than 1000 lines, you could e

Página 53

Important Information About the SPARC Enterprise T5120 and T5220 Servers 47Cleanup Output Display When Resetting ILOM (CR 6585292)Some extraneous and

Página 54 - 6591367)

48 SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Documentation ErrataTable 2-6 on page 43 of the SPARC Enterprise T5120 and T52

Página 55 - Unusable (CR 6587869)

vi SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007RAID Function 8LDOM Manager 9Hardware and Mechanical Issues 9DVD and USB Modul

Página 56

Contents viiprtdiag -v Voltage Indicators Section Has Non-Voltage Indicators (CR 6587380) 19prtdiag -v Slow To Respond on 1U (CR 6588550) 19Control-C

Página 57

viii SPARC Enterprise T5120 and T5220 Servers Product Notes • October 2007Domain ETM and LDC Deadlock When Transmit Queue Full (CR 6594506) 28raidctl

Página 58 - Documentation Errata

Contents ixIf Socketed EEProm (SCC) is Changed, SP Does Not Always Read Some SP Properties From New EEProm (CR 6596430) 39If All Platform Identity Che

Comentários a estes Manuais