Fujitsu PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Fujitsu PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle . FUJITSU PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle Solaris C120-E276-11ENZ0(A) User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User's Guide

C120-E276-11ENZ0(A)October 2011SolarisFUJITSU PCI Gigabit Ethernet4.1 Update2 / 5.0for Oracle SolarisUser's GuideSPARC Enterprise

Página 2

Figure 1.1 1000Base-SX * 2ports (SE0X7GD2X)Figure 1.2 10/100/1000Base-T * 2ports (SE0X7GD1X)- 4 -

Página 3 - Revision History

Figure 1.3 10/100/1000Base-T * 4ports (SE0X7GQ1X)Figure 1.4 10/100/1000Base-T * 4ports (SE0X7GQ2X)- 5 -

Página 4

Chapter 2 Gigabit Ethernet Card InstallationThis chapter describes the tasks necessary to install this card in your system.Install the hardware with t

Página 5 - Contents

Figure 2.1 SE0X7GD2X (with Multimode Optical Fiber Cable)- 7 -

Página 6

Figure 2.2 SE0X7GD1X (with Twisted Pair CAT5e Cable)- 8 -

Página 7 - Chapter 1 Product Outline

Figure 2.3 SE0X7GQ1X (with Twisted Pair CAT5e Cable)- 9 -

Página 8 - 1.2.1 Specifications

Figure 2.4 SE0X7GQ2X (with Twisted Pair CAT5e Cable)- 10 -

Página 9

Chapter 3 Setting InstructionsThis chapter describes the summary of environment settings required after installing this product.Install the driver and

Página 10

3.3 Environment SettingThis section explains how to edit the necessary files and use the commands(Solari 11 only) to configure the operating environme

Página 11

3. Edit the /etc/inet/netmasks fileDescribe the relationship between the network address and the netmask in the /etc/inet/netmasks file.Example of the

Página 12 - 2.3 Cable Connection

Preface PurposeThis manual describes how to install the Gigabit Ethernet card into your SPARC Enterprise system, and configure the environmentalsettin

Página 13

3.3.2 Environment Setting of IPv6 Interfaces- Solaris 10 8/07 or later1. Edit the /etc/hostname6.fjgi* fileAssign an IPv6 address or hostname and pre

Página 14

Information- The following example shows how to display an IP address and prefix length that assigned the fjgi interface.Example:When setting an IP a

Página 15

FJSV,e2ta, instance #6 (driver name: fjgi)FJSV,e2ta, instance #7 (driver name: fjgi)FJSV,e4tb, instance #8 (driver name: fjgi)FJSV,e4tb, instance #9 (

Página 16

Logical bus address Instance number Driver name"/pci@1,700000/pci@0,1/FJSV,e4ta@6,1" 3 fjgi"/pci@3,700000/pci@0/FJSV,e2sa@4" 4 fjg

Página 17

Parameter Value DescriptionLinkSpeed_A (*1)Auto (default)Any connection speed of 1000, 100, or 10Mbps is set based on negotiation with theremote devic

Página 18 - 3.3 Environment Setting

Parameter Value DescriptionTransmitMaxBD1 to 500 (*3)(default: 128)The number of buffer descriptor to waitfor an interrupt for transmitting isspecifie

Página 19 - Information

The parameter values need to be set by character strings like AutoNegotiation_A="On", LinkSpeed_A="100" andDuplexCapabilities_A=&q

Página 20

The parameter value needs to be set by a character string like fjgi0=":::8000::::::".The following is added to the fjgi.conf file:fjgi0=&quo

Página 21

Parameter Value DescriptionRemOnly flow control from the remote deviceis allowed. Flow control from the localdevice is not allowed.LocSendOnly flow co

Página 22

- From the above example, instance number and driver name for each interface can be determined. Device node of device tree Instance number Driver name

Página 23 - 3.5 Operation Mode Setup

Note- This symbol indicates that important information is given. Information- This symbol indicates that useful information is given. Handling of Th

Página 24

SE0X7GD1Xname fjgiparent /pci@3,700000/pci@0unit-addressinstance 6 is 4instance 7 is 4,1 SE0X7GQ2Xname fjgiparent /pci@4,600000/pci@0 /pci@4,600000/p

Página 25 - LinkSpeed_A="100"

Example 4: The parameters for all instances are set to "Auto-Negotiation is disabled", "Connect at 100Mbps" and "Half-Duplexo

Página 26

- When "Method 1: Setting method of new style" and "Method 2: Setting method of old style" are specified at the same time, the dri

Página 27

fjgi0=":::8000::::::";2. Reboot the system.- Setting method of old style1. Add the fjgi_mtu parameter to the fjgi.conf file. The parameter v

Página 28 - [Parameter Setting]

3.5.3 Using the ndd(1M) commandBy using the ndd(1M) command, the interface communication mode can be changed dynamically. Usually it is not necessary

Página 29

# ndd -set /dev/fjgi0 adv_1000fdx_cap 0# ndd -set /dev/fjgi0 adv_1000hdx_cap 0# ndd -set /dev/fjgi0 adv_autoneg_cap 0# ndd -set /dev/fjgi0 adv_autoneg

Página 30

Parameter Status Meaningadv_10fdx_cap Read and write10Mbps/FullDuplex Setting0: Disabled1: Enabled (default)adv_10hdx_cap Read and write10Mbps/HalfDup

Página 31

Parameter Status Meaninglp_pauseTX Read onlySet link-partner to transmit pause frame by Auto-Negotiation.0: Disabled1: Enabledlp_pauseRX Read onlySet

Página 32 - 3.5.2 JumboFrame Setup

- The values of lp_10fdx_cap, lp_10hdx_cap, lp_100fdx_cap, lp_100hdx_cap, lp_1000fdx_cap, lp_1000hdx_cap, lp_pauseTX,lp_pauseRX, and lp_autoneg_cap pa

Página 33

Propertiy Status Meaningadv_autoneg_cap Read and writeAuto-Negotiation Setting0: Auto-Negotiation Off (Forced mode)1: Auto-Negotiation On (default)mtu

Página 34

Edition Date DetailsSupport switches was addedChanged the Version 2.1 to 2.205 2005-11-11Quad Gigabit Ethernet card(PW008QG1) was supportedChanged the

Página 35

Propertiy Status Meaning_cardtype (*2) Read only0: SX (SE0X7GD2X)1: T (SE0X7GD1X/SE0X7GQ1X/SE0X7GQ2X)_Role_A (*2) Read and writeRole setting when oper

Página 36

3.5.5 FCode SettingsFCode settings must be changed when the remote device does not support Auto-Negotiation and the communication by FCode is needed(

Página 37

- Execute the following command to set Half Duplex communication, 10Mbps.ok transfer-speed=10ok half-duplex- Execute the following command to display

Página 38

- How to Return to Default FCode Settings (Auto-Negotiation Mode):- To return to default FCode settings, execute the following command from the ok pr

Página 39

The FUJITSU PCI GigabitEthernet 4.1 or later drivers support: Supported VIDs 1 - 4094Max number of VLAN interfaces 10243.7.2 Setting Up the VLAN Inte

Página 40

- To create a VLAN Interface of VID=231 for fjgi3 (this vanity name is net5), the following is used.Refer to "3.3 Environment Setting", and

Página 41 - 3.5.5 FCode Settings

Chapter 4 LinkAggregation FeatureThis chapter outlines the LinkAggregation feature, and explains the settings required to use this feature.- 4.1 About

Página 42

- LAN switch that supports the LinkAggregation (or equivalent) feature - Data Distribution Mode"Table 4.2 Data Distribution Mode" shows data

Página 43 - 3.7 VLAN Interface Setup

This mode is used for re-configuring the LinkAggregation Group of thepartner device automatically when the configuration of theLinkAggregation Group o

Página 44

Note- For more information about the dladm(1M) command, please refer to the "System Administration Guide: IP Services" and the "manpag

Página 45

ContentsChapter 1 Product Outline...

Página 46

1. Create the LinkAggregation Group- Solaris 10 8/07 or laterThe following example shows how to create the LinkAggregation Group with the fjgi0, fjgi1

Página 47

1. Describe the hostname in the /etc/hostname.aggr1 file.Example (Hostname is giga-lacp.):# cat /etc/hostname.aggr1giga-lacp2. Define the relation bet

Página 48

1. Define the relation between the IP address and the hostname in the /etc/inet/hosts file.Example (Hostname is giga-lacp and its IP address is 192.16

Página 49

4.2.1.2 Delete a LinkAggregation (dladm delete-aggr)This section explains the dladm delete-aggr command for inactivating LinkAggregation. - Synopsis-

Página 50

2. Delete the LinkAggregation Group- Solaris 10 8/07 or laterThe following example shows how to delete the "key=1" LinkAggregation Group (*3

Página 51

passive: passive mode off: off mode -T time: Specify the LACP timer short: every one second long:

Página 52

4.2.1.4 Add Interfaces to a LinkAggregation (dladm add-aggr)This section explains the dladm add-aggr command for adding interfaces to a LinkAggregati

Página 53

- Solaris 10 8/07 or later- The following example shows how to add the interface "fjgi3" to the "key=1" LinkAggregation Group:# /u

Página 54

- Synopsis- Solaris 10 8/07 or later/usr/sbin/dladm remove-aggr -d dev [-d dev] ... key -d dev: Specify the name of the physical interface (includi

Página 55

- Solaris 10 8/07 or later- The following example shows how to remove the interface "fjgi2" from the "key=1" LinkAggregation Group

Página 56

D.3 Notes...

Página 57

- Synopsis- Solaris 10 8/07 or later/usr/sbin/dladm show-aggr [-s [-i interval]] [-L] [key] -s: Specify to display the statistics. -i interval:

Página 58

- The following example shows how to display the detailed LinkAggregation Information for the "key=1" LinkAggregation Group:# /usr/sbin/dlad

Página 59

aggr1 net3 124 16.03K 147 18.82K aggr1 net4 122 15.62K 148 18.94K*: net2, net3, a

Página 60

Chapter 5 TroubleshootingThe following should be checked first to troubleshoot a problem. Is the driver software installed correctly?If the "pkgi

Página 61

Appendix A MessagesThis chapter explains messages displayed by the FUJITSU PCI GigabitEthernet driver.A.1 Console Messages from the DriverMessages f

Página 62 - 4.3 Notes

No Message Cause Workaround15 DETACH failed ([detail]) Unloading of the driver failed.After disabling the driver, re-do theprocess (disconnect in Dyna

Página 63 - Chapter 5 Troubleshooting

No Message Cause WorkaroundMaster: Communicating asMasterSlave: Communicating as Slave3 Illegal value for [ParameterName]An error was found with apara

Página 64 - Appendix A Messages

Table A.4 Messages Reported by Machine AdministrationNo Message Meaning Workaround1 fjgi_device_check: fjgi_hw_deinit failed !An error occurred durin

Página 65

Appendix B Gigabit Ethernet Card LED DiagnosisThis appendix explains the LED diagnosis function of Gigabit Ethernet cards.B.1 Location and Meaning o

Página 66

Figure B.2 10/100/1000Base-T * 2ports (SE0X7GD1X) - Meaning of the LEDs (SE0X7GD1X)The following tables show the meaning of each LED.1000M LED indicat

Página 67

Chapter 1 Product OutlineThis chapter describes the following topics.- 1.1 Key Features- 1.2 Gigabit Ethernet Card Specifications1.1 Key FeaturesThe G

Página 68

Figure B.3 10/100/1000Base-T * 4ports (SE0X7GQ1X)Figure B.4 10/100/1000Base-T * 4ports (SE0X7GQ2X) - Meaning of the LEDs (SE0X7GQ1X/SE0X7GQ2X)The foll

Página 69

ACT LED DescriptionON (Green) The card is transmitting or receiving network data.OFF The card is not transmitting or receiving network data.- 65 -

Página 70

Appendix C Using FUJITSU PCI GigabitEthernet in aCluster EnvironmentThis Appendix outlines the supported functions and setup procedure for the FUJITS

Página 71 - ACT LED Description

Appendix D Using FUJITSU PCI GigabitEthernet in SolarisContainersThis Appendix outlines the supported functions and setup procedure for the FUJITSU P

Página 72 - Cluster Environment

zonecfg:zonename> add net (Begin adding network.)zonecfg:zonename:net> set address=IP-address/prefixlen (Specify IP

Página 73 - Containers

(Note 1) In Solaris 11, the vanity name (net4) is specified as fjgi2. (Note 2) Reboot the Exclusive-IP Non-Global Zone to make this setting effecti

Página 74

zonecfg:zone1:net> set physical=net1002zonecfg:zone1:net> endzonecfg:zone1> exit (Note 1) zonecfg create -b command must be executed to crea

Página 75 - D.3 Notes

- When a VLAN interface is used in Exclusive-IP Non-Global Zones, please add a VLAN interface of the fjgi interface to the Exclusive-IP Non-Global Zon

Página 76 - - Solaris 11

1. Execute the following commands in the Global Zone.# /usr/sbin/dladm create-aggr -d fjgi0 -d fjgi1 -d fjgi2 2# zonecfg -z zone2zonecfg:zone2> set

Página 77

Appendix E Using FUJITSU PCI GigabitEthernet in OracleVM Server for SPARCThis Appendix outlines the supported functions and setup procedure for the F

Página 78

The GLDv3 compliant driver works with the following features.- The LinkAggregation (based on IEEE 802.3) by the dladm(1M) command.- Solaris Containers

Página 79 - VM Server for SPARC

- The following example shows how to add a virtual switch (vsw) device (ldm add-vsw)/opt/SUNWldm/bin/ldm add-vsw net-dev=device vswitch_name ldom (dev

Página 80

# /opt/SUNWldm/bin/ldm list-domain -l ldg1NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIMEldg1 active -n--- 5000

Página 81 - E.3 Notes

Appendix F Using FUJITSU PCI GigabitEthernet in Solaris11 Network VirtualizationThis Appendix outlines the supported functions and setup procedure fo

Página 82 - 11 Network Virtualization

Example: Creating VNICs (vnic2_1 and vnic2_2) over fjgi0 (this vanity name is net2).# dladm create-vnic -l net2 vnic2_1# dladm create-vnic -l net2 vni

Página 83

# flowadm show-flowFLOW LINK IPADDR PROTO LPORT RPORT DSFLDvnic2_1_flow vnic2_1 -- tcp

Página 84 - F.3 Notes

Appendix G PCI Slot Number and Device NameThis appendix provides a cross-reference of PCI slot numbers and device names for the following SPARC Enter

Página 85

Board Number Slot Number Device NamePCI#1-PCIE6 /pci@0,600000/pci@0/pci@9/pci@0/pci@9/pci@0/pci@9/****@0Basic PCISlotPCI#2 /pci@1,700000/****@0PCI#2IO

Página 86

Board Number Slot Number Device NamePCI#4-PCIE4 /pci@3,700000/pci@0/pci@9/pci@0/pci@0/****@0PCI#4-PCIE5 /pci@3,700000/pci@0/pci@9/pci@0/pci@1/****@0PC

Página 87

Board Number Slot Number Device NamePCI#3IOBoat(Ex)PCI#3-PCIE1/pci@12,600000/pci@0/pci@1/pci@0/pci@0/****@0PCI#3-PCIE2 /pci@12,600000/pci@0/pci@1/pci@

Página 88

Board Number Slot Number Device NameBasic PCISlotPCI#2 /pci@2,600000/****@0Basic PCISlotPCI#3 /pci@3,700000/****@0PCI#3IOBoat(X)PCI#3-PCIX1/pci@3,7000

Página 89

Item Hardware SpecificationPower RequirementsMaximum: 9.1W (SE0X7GD1X), 9.2W (SE0X7GD2X),15.0W (SE0X7GQ1X), 12.8W (SE0X7GQ2X)Connections1000Base-SX (S

Página 90

Board Number Slot Number Device NamePCI#7-PCIX4 /pci@7,700000/pci@0/pci@9/pci@0,1/****@4PCI#7IOBoat(Ex)PCI#7-PCIE1/pci@7,700000/pci@0/pci@1/pci@0/pci@

Página 91

Board Number Slot Number Device NameBasic PCISlotPCI#5 /pci@15,700000/****@0PCI#5IOBoat(X)PCI#5-PCIX1/pci@15,700000/pci@0/pci@1/pci@0/****@4PCI#5-PCIX

Página 92

- SPARC Enterprise T5120 Slot Number Device NamePCI-E#1 /pci@0/pci@0/pci@8/pci@0/pci@1/xxxxxxx@0PCI-E#0 /pci@0/pci@0/pci@8/pci@0/pci@9/xxxxxxx@0PCI-E

Página 93

- SPARC Enterprise T5440 (2CPU) Slot Number Device NamePCI-E#3 /pci@400/pci@0/pci@8/pci@0/pci@9PCI-E#4 /pci@400/pci@0/pci@8/pci@0/pci@cPCI-E#1 /pci@4

Comentários a estes Manuais

Sem comentários