238
CHAPTER 2 DEPENDENCE FUNCTIONS
2.5.1.4 Operation Frequency Control
This section describes the operation frequency setup.
Operation frequency
Set the operation frequency of MCU. Set the operation frequency using a value between 1 and 266MHz,
inclusive. This setting optimizes the communication speed between MCU and emulator.
This function can be set using the [Setup] - [Debugging Environment] - [Debugging Environment] -
[Frequency] menu or the SET FREQUENCY command.
Notes:
This setting sets the maximum frequency and will not change the actual operation frequency.
When a value smaller than the operation frequency is actually used, the emulator may malfunction.