Fujitsu M5000 Manual do Utilizador Página 118

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 310
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 117
6-26 SPARC Enterprise M4000/M5000 Servers Service Manual December 2010
6.3.1 Accessing the Tape Drive Unit
Remove the tape drive unit from the domain.
This step includes using the cfgadm command to determine the Ap_Id and
disconnecting the tape drive. See Section 4.2.1, “Removing a FRU From a Domain”
on page 4-4.
6.3.2 Removing the Tape Drive Unit
Caution Use proper ESD grounding techniques when handling components. See
Section 1.1, “Safety Precautions” on page 1-1.
1. Put a No. 1 screwdriver into the tape drive unit release hole to release the catch
that holds the tape drive unit in place (
FIGURE 6-10).
2. Remove the drive from the server and place it on the ESD mat.
FIGURE 6-10 Removing the Tape Drive
Vista de página 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 309 310

Comentários a estes Manuais

Sem comentários